W eekly Inspection 3-17 Wa r n i n g Do not insert any part of your body into the machine during I/O testing. Otherwise, serious inj ury may result.  If any problems still occur , contact our designated C/S company (STS…

100%1 / 139
Samsung Component Placer CP45NEO Series Maintenance Reference
Sensor Window
Sensitivity Control Screw
Red LED
Green LED
Lightness/Darkness Adjusting Screw
If any problems still occur, contact our designated C/S company (STS) and local
agent.
3.1.6. ANC Open/Close Sensor
Inspection
To determine the accurateness of the open/close action of the ANC shutter, check the
sensor operation through the MMI monitor.
Solution
ANC Shutte
r
ANC Open/Close
Sensor
After selecting the Diagnosis from the main menu tool bar in the MMI screen, select
the I/O command from the sub menu tool bar to check the sensor operation.
3-16
Weekly Inspection
3-17
Warning
Do not insert any part of your body into the machine during
I/O testing. Otherwise, serious injury may result.
If any problems still occur, contact our designated C/S company (STS) and local
agent.
3.1.7. Feeder Unlock Sensor
점검
Feeder unlock sensors are installed at the front and rear of this machine. The system
comes into the emergency stop status if the feeder is not installed correctly at the feeder
base. In this case, verify that the feeder is installed properly.
Front Feeder Unlock Sensor (Ligh
t
receiving section)
Front Feeder Unlock Sensor (Ligh
t
emitting section)
Samsung Component Placer CP45NEO Series Maintenance Reference
Rear Feeder Unlock Sensor (Ligh
t
emitting section)
Rear Feeder Unlock Sensor (Ligh
t
receiving section)
Caution
If the feeder loose sensor is cancelled arbitrarily, the head
and the feeder might collide as a loose feeder cannot be
sensed.
Do not cancel the feeder loose sensor arbitrarily.
Solution
After selecting the Diagnosis from the main menu tool bar in the MMI screen, select
the I/O command from the sub menu tool bar to check the sensor operation.
Warning
Do not insert any part of your body into the machine during
I/O testing. Otherwise, serious injury may result.
3-18