W eekly Inspection 3-25 If viewed from below , there is an a pproximate 1cm gap between the lighting assembly bracket and the lens. Clean any lens dust with a swab by inserting it through the gap. If necessary , dip th…

Samsung Component Placer CP45NEO Series Maintenance Reference
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” and “Reset” buttons on the front operation
panel. Conduct inspection while the motor power supply is
turned off.
Blow off lens dust from its front side using the air spray contained in the cleaning kit
provided by Samsung Techwin.
Blow off lens dust from its front side using the air spray contained in the cleaning kit
provided by Samsung Techwin.
3-24

Weekly Inspection
3-25
If viewed from below, there is an approximate 1cm gap between the lighting
assembly bracket and the lens. Clean any lens dust with a swab by inserting it through
the gap. If necessary, dip the swab in alcohol to moisten and then use it to clean the
lens.
When the lens has been cleaned using a swab moistened with alcohol, wipe the lens
surface again carefully using a clean dry swab.
3.2.2. X-Y Frame Section
Check the state of contamination and operation over all of the X-Y Frame.

Samsung Component Placer CP45NEO Series Maintenance Reference
3.2.2.1. X-Y Frame Sensor
Inspection
Check if the limit and home sensor of the X-Y frame is operating normally.
Warning
Do not disassemble the sensor intentionally as doing so
may cause collision of the machine or serious safety
danger to the operator.
Solution
After selecting the Diagnosis from the main menu tool bar in the MMI screen, select
the I/O command from the sub menu tool bar to check the sensor operation.
Y Axis (-)Limit Sensor
Y Axis Home Sensor
X Axis (-)Limit SensorY Axis (+)Limit Senso
r
X Axis Home Sensor
X Axis (+)Limit Sensor
3-26