2. Monthly maintenance items 3-18 Chapter 3 Periodic maintenance items 2.4 RM head unit Lowering RM head/nozzle shafts Maintenance of the RM head requires lowering the nozzle shafts manually in sequence as for example in…

2. Monthly maintenance items
3-17
Chapter 3 Periodic maintenance items
►
When an error message appears
Perform the conveyor tuning as following procedure.
1
Press the [Conveyor Sensor Tuning]
button at the right side of the [Unit]
- [Conveyor] screen.
2
Check the sensor condition.
Change the conveyor width again, then check
if any error message appears.
The conveyor sensor tuning finishes when no
error message appears.
►
When an error message still appears
It may be the beam receiving condition deterioration around the sensor, the sensor (amplifier) breakage,
or the fiber broken.
Remove dirt and dust on the sensor unit using a lint-free cloth or a lens blower brush, then check that no
error message appears after changing the conveyor width again.
Conveyor sensor tuning
Step 1, 2
[Sensor Tune] button
Input any conveyor width
2
1
54325-KMX-00

2. Monthly maintenance items
3-18
Chapter 3 Periodic maintenance items
2.4 RM head unit
Lowering RM head/nozzle shafts
Maintenance of the RM head requires lowering the nozzle shafts manually in sequence as for example in
"2.4.1 Inspecting and replacing the air filters" and "3.2.1 Inspecting/cleaning nozzle shaft tip".
Here describes the lowering procedure of RM head nozzle shaft.
1
Press down Z-axis of RM head.
Z-axes units are installed on both sides of RM head unit to lower the nozzle shaft.
2
Change the nozzle shaft to be lowered.
Move any nozzle shaft to beneath Z-axis by turning the N-axis gear to rotate the rotary.
c
CAUTION
Make sure that all nozzle shafts have returned to upper end after having lowered the nozzle shafts manually.
Lowering RM head nozzle shaft
1
2
Z-axis of RM head
*installed on
both sides
Press down Z-axis and
lower the nozzle shaft.
Nozzle shaft is lowered
N-axis gear
Turn N-axis gear and rotate the rotary.
The rotary rotates according to N-axis gear
533H4-KMX-00

2. Monthly maintenance items
3-19
Chapter 3 Periodic maintenance items
2.4.1 Inspecting and replacing the air filters
The filters should generally be inspected every month, although this depends on the supply air condition and
the operating time. The filters for the RM head cannot be reused. Replace the filters if contaminated.
Note that using filter insertion tool is convenient to replace multiple filters at once. The following describes
how to replace filters with the tool.
TIP
See "RM head" of "How to check for clogged nozzles (on the [Unit]-[Head] tab screen)" in chapter 2 to check vacuum
level after replacing filters. If it cannot reach normal level, perform "8.1 Cleaning inside of nozzle shaft on RM head unit".
1
Prepare for work.
e
1. Remove all items sensitive to magnetic fields
such as wristwatches and magnetic ID cards.
2. Return all nozzles (if the machine is installed
nozzle station).
3. Press the emergency stop button and detach
feeder exchange carriage.
4. Open the machine safety cover and move
the head unit frontward.
5. Place a square cloth under the head unit.
n
NOTE
When the nozzle station is not installed, remove all the
nozzles by hand.
2
Check the filter codition.
1. Remove 4 bolts on the acrylic board
mounted at the reverse side of head using a
hexagon wrench.
2. Check the filter visually through the window-
like opening.
n
NOTE
The RM head nozzle shaft can be rotated by rotating the
R-axis gear by hand. When rotating the entire holder is
required, rotate the N-axis gear by hand.
3
Detach the filter.
1. As shown in the figure at right, push out the
filter from the end of nozzle shaft using a
flat-head precision screwdriver.
2. Turn the N-axis gear by hand to rotate the
rotary and detach the filters on the opposite
side.
n
NOTE
The filters for the RM head cannot be reused once they
are detached.
As a general guide, the filters should be replaced once
every month, although this depends on the operating time
of the machine. Periodic filter replacement is
recommended.
The filter for RM head:
• 20-pack (KMB-M3856-00X)
• 1000-pack (KMB-M3857-01X)
Removing acrylic board
Step2
Bolt
Acrylic board
53337-KMX-00
Removing filters
Step 3
Precision screwdriver
Front side of head
Filter
Turn N-axis gear
to rotate the rotary
Turn R-axis gear
to rotate the nozzle
shaft
Nozzle shaft
53338-KMX-00