Printer 710-810 v9 ProFlow ATX.pdf - 第21页

PROFLOW ATX ADJUSTMENTS & SETTINGS Chapter Issue 6, Jan 16 Technical Reference Manual 12.21 recharges. NOTE When full the maximum allowable heigh t difference between the lef t and right hand Print Medium Level Indic…

100%1 / 56
PROFLOW ATX
ADJUSTMENTS & SETTINGS
12.20 Technical Reference Manual Chapter Issue 6, Jan 16
Initial Fill To fill the ProFlow ATx unit for the first time or from empty following cleaning or
maintenance, proceed as follows;
1. Check that the Conditioning Duration is set at 7 seconds.
2. Set the Grid Speed Coefficient to 100%.
3. Set the Recharge Volume to 50.
4. Select Recharge ProFlow.
5. Select Recharge ProFlow.
6. Select Condition ProFlow.
7. Select Prime ProFlow.
8. Select Recharge ProFlow.
9. Select Recharge ProFlow.
10. Select Condition ProFlow.
11. Select Prime ProFlow.
NOTE
Ensure that both Print Medium Level Indicator Pistons are in the fully down
position.
12. Change the Recharge Volume to 20.
13. Select Recharge ProFlow (this is the fifth recharge).
14. Select Condition ProFlow.
15. Select Prime ProFlow.
16. Repeat Recharge ProFlow, Condition ProFlow and Prime ProFlow until
the head is full.
NOTE
The head is full when the Print Medium Demand Sensor’s red indicator light
is not lit. The fill procedure should be completed with a total of 7 or 8
Print Medium Level Indicator Pin
Print Medium Level Indicator Pin
Fully Down Position
Print Medium Level Indicator Pins - Down Position
7mm
PROFLOW ATX
ADJUSTMENTS & SETTINGS
Chapter Issue 6, Jan 16 Technical Reference Manual 12.21
recharges.
NOTE
When full the maximum allowable height difference between the left and
right hand Print Medium Level Indicator Pins is 3mm for a 300mm wide head
and 5mm for a 400mm wide head.
17. After the head is filled, set the Grid Speed Coefficient to 30%.
View on Print Medium Demand Sensor
Indicator -
Print Medium
Required
Indicator -
Head Full
Dimension - 3mm Maximum (300mm Head)A
5mm Maximum (400mm Head)
A
Print Medium Level Indicator Pins - Maximum Allowable Height Difference
PROFLOW ATX
REPLACEMENT PROCEDURES
12.22 Technical Reference Manual Chapter Issue 6, Jan 16
REPLACEMENT PROCEDURES
Transfer Head Base Cover
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
Fitting 1. Ensure the two locking clips on the base cover are unlocked; in the up
position.
View on Left Hand Front Corner
Base Cover
Locking Clips
Transfer Head Sealing Plug