PROFLOW ATX REPLACEMENT PROCEDURES Chapter Issue 6, Jan 16 Technical Reference Manual 12.35 Fitting the Print Medium Cartridge MANDA TOR Y T OXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN. MANDA TOR Y T OXIC C…

PROFLOW ATX
REPLACEMENT PROCEDURES
12.34 Technical Reference Manual Chapter Issue 6, Jan 16
Levelling the
Transfer Head
For an even application of print medium, during both the forward and rearward
print-strokes, obtain equal pressure on the tips of the wiper blades by levelling
the transfer head against the stencil when under system pressure. To adjust
the level of the transfer head, carry out the following on the ProFlow ATx mount:
1. Loosen the two transfer head pin mount lock screws, using a 3mm Allen key.
2. Evenly adjust the two transfer head levelling screws, using a 2mm Allen key.
Turning the levelling screws clockwise lowers the front of the transfer head.
Turning the levelling screws counter-clockwise raises the front of the trans-
fer head.
3. Tighten the two transfer head pin mount lock screws, using a 3mm Allen key.
4. Perform a print operation.
5. Inspect the print medium application; if further levelling is required, repeat
the procedure.

PROFLOW ATX
REPLACEMENT PROCEDURES
Chapter Issue 6, Jan 16 Technical Reference Manual 12.35
Fitting the Print
Medium Cartridge
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
WARNING
MOVING PARTS. MOVING PARTS ARE PRESENT IN THE VICINITY OF THIS
WARNING LABEL, THESE PARTS HAVE THE POTENTIAL TO CAUSE INJURY.
NOTE
The following procedure assumes that an empty cartridge is fitted; if this is not
the case, open the lever arm (step 4) and begin the procedure at step 9 - “Fit
the new print medium cartridge to the filler tube assembly”.
To fit a new print medium cartridge to the ProFlow ATx system, carry out the
following:
1. Select Open Cover Commands.
2. Select Carriage to Front.
3. Open the machine cover.

PROFLOW ATX
REPLACEMENT PROCEDURES
12.36 Technical Reference Manual Chapter Issue 6, Jan 16
4. Pull the lever arm towards the left side of the machine.
5. Rotate the print medium cartridge anti-clockwise 90°.
NOTE
During removal of the print medium cartridge, the filler tube assembly
remains attached to the nozzle of the cartridge. You cannot remove the print
medium cartridge from the cartridge holder assembly until the cartridge has
been fully rotated 90° and the filler tube adaptor has reached the unlocked
position.
View on Left Front of ProFlow ATx System
View on Left Front of ProFlow ATx System