40 0712-001 1 1.3 Inspection, Cleaning, and Lubrication Spots 1 1.3.2 V acuum Nozzle Inside the V acuum Nozzle Every Month Cleaning Blow air into the vacuum hole. V acuum Nozzle Hole Every Month Cleaning Blow air into th…

390712-001
11.3 Inspection, Cleaning, and Lubrication Spots
11.3 Inspection, Cleaning, and Lubrication Spots
11.3.1 Nozzle Stocker
(1) Wipe off old grease with an oiled rag.
Take ample care not to leave
the waste threads after the
old grease is wiped off.
(2) Apply new grease by hand or with
a brush.
Nozzle Storage Section
Every Month Cleaning
Wipe off dirt and dust with a rag.
Cam Follower
Every Month Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Note
Fig. 14 Nozzle Stocker

400712-001
11.3 Inspection, Cleaning, and Lubrication Spots
11.3.2 Vacuum Nozzle
Inside the Vacuum Nozzle
Every Month Cleaning
Blow air into the vacuum hole.
Vacuum Nozzle Hole
Every Month Cleaning
Blow air into the vacuum hole.
Vacuum Nozzle End
Every Month Cleaning
Clean it with a rag.
Diffusion Plate
Upper Surface of Diffusion Plate
Every Week Inspection/Cleaning
Check that no dirt and dust adheres to the
upper surface of the diffusion plate.
If necessary, wipe them off with the lens
cleaning cloth.
Never use neither solvent nor
ethanol.
Otherwise, the diffusion plate
may crack.
Lower Surface of Diffusion Plate
Every Week Cleaning
When dirt and dust have accumulated on
the lower surface of the diffusion plate,
wipe them off with the lens cleaning cloth.
Never use neither solvent nor
ethanol.
Otherwise, the diffusion plate
may crack.
Notice
Notice
Fig. 15 Vacuum Nozzle

410712-001
11.3 Inspection, Cleaning, and Lubrication Spots
11.3.3 Placement Head
Linear Guides (3 places)
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Apply new grease using a syringe.
Lubrication should be applied every 3
months after the initial month.
The nozzle to be used is the nozzle
No. 19 (brown).
Take care so that any grease
is not attached on the sensor
when apply grease.
Saucer (3 places)
Every 3 Months Cleaning
No.19
Ball Screw
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Apply new grease using a syringe.
Lubrication should be applied every 3 months
after the initial month.
The nozzle to be used is the nozzle
No. 19 (brown).
No.19
Sensor
Notice
Note
Note
Wipe off old grease with an oiled rag.
Fig. 16 Placement Head