LA 404-2 Pattern Control System
23
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Quick Programming Guide
This Quick Programming Guide explains the organization of the various menus in Administrator-, Setup- and Operator modes.
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Bead Type Channel 4
Normal Continuous
Modulation Seam
Autospot Random
Chan 4 Compensation
Pull−in 00.0 mm
Drop-out 00.0 mm
Set speed 60 m/min
Chan 3 Compensation
Pull-in 00.0 mm
Drop-out 00.0 mm
Set speed 60 m/min
Chan 2 Compensation
Pull-in 00.0 mm
Drop-out 00.0 mm
Set speed 60 m/min
Chan 4 Driver Setup
Peak voltage 32 V
Spike time 1.8 ms
Hold voltage 5 V
Chan 3 Driver Setup
Peak voltage 32 V
Spike time 1.8 ms
Hold voltage 5 V
Chan 2 Driver Setup
Peak voltage 32 V
Spike time 1.8 ms
Hold voltage 5 V
Administrator Mode:
Program 1..100
Speed 60 m/min
Work rate 0/hr
Total 0
V3.26
Start
Administrator
Channel Assignment
Channel 1 Active
Trigger 1
Trigger Assignment
Channel 2 Active
Trigger 1
Trigger Assignment
Channel 3 Active
Trigger 1
Trigger Assignment
Channel 4 Active
Trigger 2
Setup Trigger 1
Trigger Light On
JAM detection Off
JAMtolerance 5 mm
Setup Trigger 2
Trigger Light On
JAM detection Off
JAMtolerance 5 mm
Setup Trigger 3
Trigger Light On
JAM detection Off
JAMtolerance 5 mm
Setup Trigger 4
Trigger Light On
JAM detection Off
JAMtolerance 5 mm
Trigger 1 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 2 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 3 Settings
Prod. length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 4 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Pressure 1 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Pressure 2 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Purge Pressure
Run−up 1 10%
Run−up 2 10%
Purge Mode Purge
Chan 1 Driver Setup
Peak voltage 32 V
Spike time 1.8 ms
Hold voltage 5 V
Chan 1 Compensation
Pull-in 00.0 mm
Drop-out 00.0 mm
Set Speed 60 m/min
Bead Type Channel 3
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 2
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 1
Type #type
Dly1: 251 Dur1: 25
Dly3: 277 Dur3: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Program 01
Save as 01 No
Recall 01 No
Copy CH# to CH# No
Warnings
Encoder Scaling
Encoder Single
Custom 1.000 ppmm
Direction Forward
Low Speed Setting
Start 10 m/min
Stop 5 m/min
System Settings 1
Language English
Autostart Off
Rem enable Active
System Settings 2
Trigger memory Off
Clipping Off
Tip seal Settings
Mode Automatic
Dwell time 3.0 s
Start
Max dot 100 m/min
#type: Normal, Continuous, Autospot, Dot, Random, Random Stitch

LA 404-2 Pattern Control System
24
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Setup mode:
Program 1..100
Speed 60 m/min
Work rate 0/hr
Total 0
V3.26
Setup
Trigger Assignment
Channel 1 Active
Trigger 1
Trigger Assignment
Channel 2 Active
Trigger 1
Trigger Assignment
Channel 3 Active
Trigger 1
Trigger Assignment
Channel 4 Active
Trigger 2
Trigger 1 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 2 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 3 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Trigger 4 Settings
Prod.length 100 mm
GTO 50 mm
Masking 5 mm
Pressure 1 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Pressure 2 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Purge Pressure
Run−up 1 10%
Run−up 2 10%
Purge Mode Purge
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Program 01
Save as 01 No
Recall 01 No
Copy CH# to CH# No
Warnings
Start
Start
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Operator mode:
Program 1..100
Speed 60 m/min
Work rate 0/hr
Total 0
V3.26
Operator
Pressure 1 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Pressure 2 Settings
Speed1 0 P1 0%
Speed2 100 P2 80%
Min 0% Max 100%
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Dly1: 251 Dur1: 25
Dly2: 277 Dur2: 25
Dly3: 303 Dur3: 25
Dly4: 329 Dur4: 25
Program 01
Save as 01 No
Recall 01 No
Copy CH# to CH# No
Warnings
Start
Start
Bead Type Channel 4
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 3
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 2
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 1
Type #type
Bead Type Channel 4
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 3
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 2
Normal Continuous
Modulation Seam
Autospot Random
Bead Type Channel 1
Type #type

LA 404-2 Pattern Control System
25
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
System Setup
The pattern controller can be customized with several setup options by
using the Administrator, Setup or Operator modes. Refer to the Quick
Programming Guide for the sequence of menu screens that are used to
program the pattern controller. After switching the unit on, Operator mode is
always activated.
The cyclical sequence of modes is Operator, Setup, Administrator mode.
Setup mode can only be accessed through Operator mode. Administrator
mode can be accessed from Setup mode and Operator mode.
NOTE: After being switched on, the pattern controller perform a short
initializing procedure that includes a self-test and setup program. This
procedure takes between 10 - 15 seconds to complete.
Press the top SETUP button to access the next menu. Press the bottom
SETUP button to access the next menu.
Resetting the Default Settings
To reset the LA404-2 pattern controller to its default settings, press the two
SETUP-buttons while switching the unit on.
CAUTION: All the Administrator settings and program data from Program 1
are reset to their default values.
Not resetting all the data has the advantage that older working programs
are retained after the reset process. Resetting is only usually necessary
when the administrator settings have been changed and the settings are no
longer available.