LA 404-2 Pattern Controller Manual.pdf - 第58页

LA 404-2 Patt ern Control Sys tem 52 P/N 7 1 19995A 2006 Nordson Corporation LA 4 04- 2 Is sued 12/06 System Settings 1 This setup menu is used to configure the operating language, automatic and manual pattern controller…

100%1 / 74
LA 404-2 Pattern Control System
51
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Low Speed Settings
This setup menu is used to configure the minimum operational line speed
above which the guns will begin dispensing, and below which the guns will
stop dispensing adhesive. Setting this feature prevents a puddle of
adhesive from forming when the line stops.
CAUTION: When using the Random Dot and Dot Bead modes, it is
recommended to set a maximum speed (Max Dot) which must not be
exceeded due to the risk of the guns overheating. The standard value is
100 m/min, but it can be adjusted.
NOTE: If the production machine speed is above the maximum dot speed
(Max Dot), a normal bead is applied (also refer to Page 15).
NOTE: Low speed settings override the line speed settings for continuous
bead patterns.
Low Speed Setting
Start 0 m/min
Stop 1 m/min
Max Dot 100 m/min
O684
1. To set start speed
a. Press the or button for the cursor to appear beside Start.
b. Press the or button to set the desired value from
0 - 600 m/min.
2. To set stop speed
a. Press the or button for the cursor to appear beside Stop.
b. Press the or button to set the desired value from
0 - 600 m/min.
3. To set max dot speed
a. Press the or button for the cursor to appear beside Max Dot.
b. Press the or button to set the desired value from
0 - 600 m/min.
NOTE: The Max Dot speed is relevant for the following bead types:
Autospot, Dot and Random Dot.
LA 404-2 Pattern Control System
52
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
System Settings 1
This setup menu is used to configure the operating language, automatic
and manual pattern controller runup and remote activation.
When the Autostart function is on, the pattern controller is automatically set
to Run mode when the unit is switched on. When set to off, the pattern
controller always enters STAND BY when the unit is switched on.
If remote enable is set to Active, an external contact closure is required on
the remote input plug to activate pattern generation.
System Setting 1
Language English
Autostart Off
Rem enable Active
O685
1. To set the language
a. Press the or button for the cursor to appear beside the
language.
b. Press the or button to select the appropriate language.
2. To set Autostart
a. Press the or button for the cursor to appear beside On or Off.
b. Press the or button and select On or Off.
NOTE: The Autostart feature controls the enabling and disabling of
pattern generation after switching on. If it is disabled, all the channels
are set to STAND BY after switching on. If it is enabled, all the channels
that were in running when the system was switched off start running
again when switched on again. The default setting is Autostart Off.
LA 404-2 Pattern Control System
53
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
3. To set remote enable
a. Press the or button for the cursor to appear beside Active.
b. Press the or button to select Active or Inactive.
When set to Active, ensure the following:
Connect the plug provided in the ship-with kit to the Remote
Input connector, refer to Remote Enable Plug explained earlier
in the manual.
Connect the 24 V
DC-
plug (Remote input, pin 1) on the input
Remote enable (Remote input, pin 7) with an electrically isolated
contact; refer to plug Remote input.
To bypass this function, set the Remote enable parameter to