LA 404-2 Pattern Controller Manual.pdf - 第62页

LA 404-2 Patt ern Control Sys tem 56 P/N 7 1 19995A 2006 Nordson Corporation LA 4 04- 2 Is sued 12/06 Tr oubleshooting Refer to t he flow chart on the opposite page to trou bleshoot basic patte rn controller problems. If…

100%1 / 74
LA 404-2 Pattern Control System
55
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Tip Sealer Settings
This setup menu is used to configure the operation of the tip sealer output.
The tip seal output is capable of driving a 24 VDC solenoid valve. A
dedicated photosensor input in addition to the four-triggers has been
provided to trigger the tip seal logic.
The tip seal valve output operates in either automatic mode or forced open
mode.
In forced open mode, the tip sealer output is continuously activated.
In automatic mode, the tip sealer output is activated prior to any gun
being activated. The output is also activated when triggered by the
tip seal photosensor or the assigned channel trigger. If a trigger
signal is not received in a programmable period of time, the tip seal
output is deactivated.
Tip Sealer Settings
Mode Automatic
Dwell time 3.0 s
O687
1. To set tip sealer mode
a. Press the or button for the cursor to appear beside Mode.
b. Press the or button to Forced Open or Automatic.
2. To set Dwell time
a. Press the or button for the cursor to appear beside Dwell time.
b. Press the or button to set the numeric value from 0.0 - 99.0 s.
LA 404-2 Pattern Control System
56
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Troubleshooting
Refer to the flow chart on the opposite page to troubleshoot basic pattern
controller problems. If the problem persists, contact your local Nordson
representative (refer to Nordson International).
The Nordson customer service representative will need the engine software
version in order to assist in troubleshooting the pattern controller effectively.
Make sure you have the engine software version number prior to calling
customer service.
Initializing
Administrator
V3.26
Engine Software Version
O688
Fig. 11 Location of Engine Software Version Number
Note the engine software version number from the initialization menu
screen. The information can also be obtained during the software download
process; refer to Software Upgrade given earlier.
LA 404-2 Pattern Control System
57
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Basic Troubleshooting Flowchart
Fix
Fix
No
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
No
Yes
Yes
No
Yes
Yes
No
Yes
No
Start Here:
Gun fires?
Plug in power
supply
Power supply
plugged in?
Increase
speed
Turn switch
on
Power switch
on?
Is line speed
above low speed?
Start line
Line
running?
Trigger and
cabling OK?
Trigger light
active?
Replace controller
Enter pattern
Pattern
entered?
Encoder
indicator
on/flashing?
Check encoder wheel and
cable
Replace controller
Gun output
light active?
Is spike time
properly set?
Increase
spike time
Gun or gun cable problem
Yes
No
Press STAND BY
button. Verify
remote enable by
parent machine.
Green LED on?
O689