LA 404-2 Pattern Control System 39 P/N 7 1 1 9995A 2006 Nordson Corporation LA 4 04- 2 Is sued 12/06 Continuous Beads When this bead type is s elected, the outputs are activ ated if the line speed is above the s tart spe…

100%1 / 74
LA 404-2 Pattern Control System
38
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
1. To set Dly (delay)
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to set the desired delay value from 00.0
- 9999 mm.
2. To set Dur (duration or length)
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to set the desired duration value from 00.0
- 9999 mm.
NOTE: This menu screen automatically adjusts the start of successive
intervals during setup to prevent overlapping of bead. When incrementing
delay or duration settings, the bead editor will stop at the overlap value. To
continue incrementing delay or duration settings, release and press the
button.
Gun Trigger
Dur1
Dly1
Dur2
Dly2
6640037A
Bead 1 Bead 2
Direction of travel
Next product
Direction of travel
Leading edge Leading edge
Gun-Trigger Offset
(GTO)
Fig. 6 Bead Patterns
To delete a bead
1. Press the or button for the cursor to appear beside Dur 1 - 4.
2. Press and hold the button, the numeric value will be decrement to 1
(one).
3. To delete, release and press the button again for the numeric value to
go down to zero. The bead will be replaced by the subsequent bead.
LA 404-2 Pattern Control System
39
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Continuous Beads
When this bead type is selected, the outputs are activated if the line speed
is above the start speed and deactivated if the line speed drops below the
stop speed. With continuous gluing, no pattern is programmed and no
trigger signal is required.
NOTE: Low speed settings will override the line speed settings for
continuous bead patterns.
Continuous Bead
Start 5 m/min
Stop 5 m/min
O674
1. To set Start:
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to set the desired Start value from
0 - 600 m/min.
2. To set Stop
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to set the desired Stop value from
0 - 600 m/min.
LA 404-2 Pattern Control System
40
P/N 7119995A
2006 Nordson Corporation
LA 404-2
Issued 12/06
Autospot Beads
With this bead type the channel output operates in dot mode when the
pattern controller is below the activation speed and operates in normal
mode when above the activation speed. This bead type is used to relieve
residual pressure after a sudden machine stop.
NOTE: If the production machine speed is above the maximum dot speed
(Max Dot), the maximum dot speed is used (also refer to Page 51).
6640041A
2
1
Activation speed
Fig. 7 Autospot Bead Pattern for Decelerating Line Speed
Autospot Parameters
Time 0.1 ms
Pitch 5 mm
Normal 25 m/min
O675
1. To set the size of each dot (Time):
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to enter the desired gun-on time value
from 0.1 - 50.0 ms.
2. To set the pitch between dots:
a. Press the or button for the cursor to appear beside the numeric
value.
b. Press the or button to enter the desired Pitch value from
2 - 9999 mm.