Specification SIPLACE X-Series规格说明书1.pdf - 第52页

52 Technical Data Electrical Connection, Interfaces and Compressed Air Connection Compressed air connection SMEMA/Siemens interface PC and LAN connection Power connector 5 x 6 mm² cable with CEKON plug 5 x 32 A (3 x 208 …

100%1 / 72
51
Technical Data
Electrical Ratings and Compressed Air Supply
Electrical ratings
Supply voltage 3 x 200 VAC ± 5%; 50/60 Hz (Japanese version)
3 x 208 VAC ± 5%; 50/60 Hz (U.S.A. version)
3 x 230 VAC ± 5%;50/60 Hz
3 x 380 VAC ± 5%;50/60 Hz
3 x 400 VAC ± 5%; 50/60 Hz (European version)
3 x 415 VAC ± 5%;50/60 Hz
Fuses 3 x 32 A (3 x 200 VAC / 3 x 208 VAC / 3 x 230 VAC)
3 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Power connector 5 x 6 mm² cable with CEKON plug 5 x 32 A (3 x 200 VAC/208 VAC/230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A (3 x 380 VAC/400 VAC/415 VAC)
Nominal apparent power SIPLACE X4: 4.7 kVA
SIPLACE X3: 4.1 kVA
SIPLACE X2: 3.3 kVA
Active power SIPLACE X4: 2.7 kW
SIPLACE X3: 2.15 kW
SIPLACE X2: 1.83 kW
Rated current consumption SIPLACE X4: 11.3 A / 3 x 400 VAC
SIPLACE X3: 9.7 A / 3 x 400 VAC
SIPLACE X2: 8.1 A/ 3 x 400 VAC
Compressed air supply
Compressed air pressure 0.5 MPa = 5.0 bar (p
min
) to 1.0 MPa = 10 bar (p
max)
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compr. air connection R 3/4" internal thread (pipe thread) with 1/2" hose connector
Type of machine Placement head configuration Compressed air consumption
a
without vacuum pump
b
a) Under normal atmospheric conditions at 20°C and 1013 hPa.
b) It is not possible to use the vacuum pump with the 20-nozzle Collect&Place head under software version
SR.605.xx.
SIPLACE X4
SIPLACE X3
SIPLACE X2
C&P20/C&P20/C&P20/C&P20
C&P20/C&P20/C&P12/C&P12
C&P20/C&P20/C&P12/C&P6
C&P20/C&P20/C&P6/C&P6
TH/TH/TH/TH
C&P20/C&P20/C&P20
C&P20/C&P20/C&P12
C&P20/C&P20/C&P6
TH/TH/TH
C&P20 / C&P20
C&P20/C&P12
C&P20/C&P6
TH / TH
960 Nl/min
880 Nl/min
880 Nl/min
880 Nl/min
400 Nl/min
720 Nl/min
680 Nl/min
680 Nl/min
300 Nl/min
480 Nl/min
440 Nl/min
440 Nl/min
200 Nl/min
Compressed air specification
Particle size 5 µm ISO class 3
Particle density 5 mg/m³ ISO class 3
Maximum oil content 0,01 mg/m³ ISO class 1
Pressure dewpoint + 3°C ISO class 4
52
Technical Data
Electrical Connection, Interfaces and
Compressed Air Connection
Compressed air
connection
SMEMA/Siemens interface
PC and LAN connection
Power connector
5 x 6 mm² cable with CEKON plug 5 x 32 A (3 x 208 VAC / 3 x 230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Power supply connection
53
Technical Data
Dimensions and Set-up Conditions
Length
with both extension kits
with one extension kit
with no extension kits
2380 mm
2103 mm
1826 mm
Width of the basic machine
X4 with component changeover table (locations 1 + 4)
X4 with component changeover table (locations 2 + 3)
X3 with component changeover table (locations 1 + 4)
X3 with component changeover table (locations 2 + 3)
X2 with component changeover table (locations 1 + 4)
X2 with component changeover table (locations 2 + 3)
with monitors
with keyboards
2815 mm
2815 mm
2815 mm
2395 mm
2395 mm
2395 mm
2766 mm
2804 mm
Height of the machine
with indicator lamp
with folded-up protective covers
max. 1863 mm
1990 mm (PCB transport height 830 mm)
2060 mm (PCB transport height 900 mm)
2090 mm (PCB transport height 930 mm)
2112 mm (PCB transport height 950 mm)
Machine ground clearance 120 mm (PCB transport height 830 mm)
190 mm (PCB transport height 900 mm)
220 mm (PCB transport height 930 mm)
240 mm (PCB transport height 950 mm)
Weight
X4 (machine with component changeover table)
X4 (full configuration with feeder modules)
X3 (machine with component changeover table)
X3 (full configuration with feeder modules)
X2 (machine with component changeover table)
X2 (full configuration with feeder modules)
3880 kg
4255 kg
3790 kg
4171 kg
3705 kg
4086 kg
Footprint
X4, X3 and X2 6.70 m²
Load per unit area
a
X4
X3
X2
a) The load per unit area calculation included an additional working space of 0.5 m on each side of the
machine.
5.98 kN/m²
5.84 kN/m²
6.20 kN/m²
Number of machine feet 6
Maximum noise emissions 75 dB (A)
Room temperature between 15°C and 35°C
Atmospheric humidity 30 to 75 % (no higher than 45% on aver-
age to prevent any possibility of conden-
sation on the machine)