00194655-01.pdf - 第43页

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 43 : Remove the si de pa nel. 2 2 : Loosen the screws on the approach gua rd and remove the guard. 2 2 2 2 2 2 Screws Screw s

100%1 / 74
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
42
2.4 Removing the protective covers
: Loosen the screws and remove the panels on the front of the MTC2.
2
2
2
2
2
2 screws on the right-hand side
2 screws on the left-hand side
Remove the panel on both sides
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
43
: Remove the side panel.
2
2
: Loosen the screws on the approach guard and remove the guard.
2
2
2
2
2
2
Screws
Screws
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
44
: Loosen the screws on the rear side panel and remove the panel.
Detach the earth bonding.
2
2
: Also remove the plates and panels on the other side; the screw pattern is a mirror image in the
same positions.
: Unscrew the earth bonding on the left safety door.
2
Screws
Unscrew
earth bonding