Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 46 : Loosen t he five scr ews on the si de cover and remove the cover . Detach the ea rth bonding. Do not remove the side cover from…

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
45
: Unscrew the top door stop.
2
2
: Remove the split-pins from both door hinges and pull the pins up and out.
Hold the door firmly as you do so.
Remove the door.
2
2
: Remove the door on the other side of the MTC2 in the same way.
2
Remove the split pins
Pull out the pins

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
46
: Loosen the five screws on the side cover and remove the cover.
Detach the earth bonding.
Do not remove the side cover from tray supply 1.
2
2
2
2
2
2
2
2
2
2
2
4 screws
1 screw at the top

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
47
: Loosen the screw for the top frame in order to be able to remove the top frame.
2
2
2
2
2
2
2
2
2
2
2
2
Screw for
top frame