Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 56 : Push the motor inwards on both sides in order to slacke n the belts. : Remove the toothed belts on both sides. : Remove the mot…

100%1 / 74
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
55
: Remove the two setscrews for setting the belt tension for the motor supports on both sides of
the MTC2.
2
2
: Loosen 4 clamping screws on each side.
2
2
2
Remove the
setscrews
4 clamping screws
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
56
: Push the motor inwards on both sides in order to slacken the belts.
: Remove the toothed belts on both sides.
: Remove the motor.
: Loosen the screws on the cover of the feed axis and remove the cover.
2
: Raise the tray supply manually and place a suitable lifting device (such as the wooden block
in the photograph) beneath it so it cannot slip down.
2
2
2
2
2
2
2
2
2
2
Lifting device
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
57
: Unscrew the locking screw on both sides.
2
2
: On both sides, remove the groove nut using a groove nut spanner and a fork wrench.
The photograph below shows which way to turn the spanners.
2
2
2
2
2
Locking screw
Groove nut