00194655-01.pdf - 第53页

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 53 : Remove the bottom left side plate on both sides of the MTC2, including th e earth bonding (hexagon socket + hexagon) 2 : Discon…

100%1 / 74
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
52
: Loosen the screw beside the plug you have just removed.
2
: Remove the top frame.
: Loosen the three screws on the bottom frame of the MTC2 and remove the plate.
2
Screw
Previously removed plug
Three screws
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
53
: Remove the bottom left side plate on both sides of the MTC2, including the earth bonding
(hexagon socket + hexagon)
2
: Disconnect the sensors from both motors.
2
Mark the sensors to indicate whether they were plugged in at the top or bottom. 2
2
2
Side plate
Remove the sensors
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
54
: Remove the sensor mounts (2 screws).
2
2
: Dismantle the synchronizing disk / thrust sleeve from the spindle.
2
2
2
Sensors
Sensor
mounts
Spindle synchro-
nizing disk