00194655-01.pdf - 第47页
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 47 : Loosen the screw for the top frame in or der to be able to remove the top fra me. 2 2 2 2 2 2 2 2 2 2 2 2 Screw for top frame

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
46
: Loosen the five screws on the side cover and remove the cover.
Detach the earth bonding.
Do not remove the side cover from tray supply 1.
2
2
2
2
2
2
2
2
2
2
2
4 screws
1 screw at the top

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
47
: Loosen the screw for the top frame in order to be able to remove the top frame.
2
2
2
2
2
2
2
2
2
2
2
2
Screw for
top frame

Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
48
2.5 Removing the spindle
If you did not move the tray supplies into the bottom position before starting the conversion, then
you must connect the brake release. 2
: Unplug the two cables for controlling the tray supplies.
2
: Connect the brake release at the terminals in order to be able to move the spindle.
2
Remove 2 plugs
Connect the brake release here