F4000N_revD.pdf - 第35页
F4000N Series Operating Manual Section 5: Point T ype & Function Reference Part # 562187N - 1 Rev . D Sep 201 2 34 © 20 12 Fisnar Inc. 1.3 Line Passing Registers the current XYZ locatio n as a Line Passing point. T h…

F4000N Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187N-1
Rev. D Sep 2012
33
© 2012 Fisnar Inc.
1. F1 (Point Menu)
Below is a list of functions which are found under the F1/ENTER key. These functions are
„point-type‟ functions, meaning that the values applied will occupy one memory address.
Please see SECTION 6:Sample Programs for additional programming examples.
1.1 Dispense Dot
Registers the current XYZ location as a dispense point for dot dispensing.
The dispense time and wait time must be set in a previous memory address by registering
a Point Dispense Setup instruction.
The upward motion of the tip after dispensing can be controlled by registering a Dispense
End Setup instruction and / or a Z Clearance instruction in a previous memory address.
Dispense End Setup and Z Clearance instructions are registered using the F4 (SETUP)
key.
See also SECTION 5:5.3 (Point Dispense Setup), SECTION 5:5.4 (Dispense End
Setup) and SECTION 5:5.5 (Z Clearance).
1.2 Line Start
Registers the current XYZ location as a Line Start point for line dispensing.
The line speed must be set in a previous memory address by registering a Line Speed
instruction using the F4 (SETUP) key.
Dispense delay times used at Line Start and Line End points can be controlled by
registering a Line Dispense Setup instruction in a previous memory address. The Line
Dispense Setup instruction is registered by pressing the F4 (SETUP) key.
See also SECTION 5:5.1 (Line Speed) and SECTION 5:5.2 (Line Dispense Setup).

F4000N Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187N-1
Rev. D Sep 2012
34
© 2012 Fisnar Inc.
1.3 Line Passing
Registers the current XYZ location as a Line Passing point. This is a location on the line
where the tip changes direction, such as at the corner on a rectangle.
1.4 Circle
Registers a circle, where the circle‟s center is at the current XYZ location. To register a
circle, jog the tip to the circle‟s center and press F1/ENTER, and then press the key 4 (for
circle). The display will prompt you to type the following data:
Diameter: Type the diameter of the circle and press ENTER.
Over Angle: (The value is from 1~360). After dispensing the circle, while going through
an extra part of the circle defined by the Over Angle, the dispenser will be
turned OFF.
Z Lift: 1. Yes 2. No
Selection: If you want the Z-axis (tip) to lift while going through the Over Angle, you
must select 1. Otherwise: select 2.
The speed must be set in a previous memory address by registering a Line Speed
instruction using the F4 (SETUP) KEY.
Dispense delay times used at the start of the circle and at the end of the circle can be
controlled by registering a Line Dispense Setup instruction in a previous memory
address. The Line Dispense Setup instruction is registered by pressing the F4(SETUP)
key.
See also SECTION 5:5.1 Line Speed and SECTION 5:5.2 Line Dispense Setup.
The upward motion of the tip after dispensing can be controlled by registering a Dispense
End Setup instruction and / or a Z Clearance instruction in a previous memory address.
Dispense End Setup and Z Clearance instructions are registered using the F4(SETUP)
key.
See also SECTION 5:5.4 Dispense End Setup and SECTION 5:5.5 Z Clearance.

F4000N Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187N-1
Rev. D Sep 2012
35
© 2012 Fisnar Inc.
1.5 Arc Point
Registers the current XYZ location as an Arc Point. Arc points are used to dispense
material along an arc or circular path.
See SECTION 4: Programming Example, for an example of the use of an Arc point.
1.6 Line End
Registers the current XYZ location as a Line End point.
The dispense delay time used at the end of the line can be controlled by registering a Line
Dispense Setup instruction in a previous memory address. The Line Dispense Setup
instruction is registered by pressing the F4 (SETUP) key.
See also SECTION 5:5.2 Line Dispense Setup.
The upward motion of the tip after dispensing can be controlled by registering a Dispense
End Setup instruction and / or a Z Clearance instruction in a previous memory address.
Dispense End Setup and Z Clearance instructions are registered using the F4 (SETUP)
key.
1.7 End Program
Registers the current memory address as the end of the program. The end program
instruction will cause the tip to return to the home position at the end of the program cycle.