00193922-01.pdf - 第165页
User Manual SIPLAC E HF Series 4 Setting up and commissioning Software Version SR.505.xx 05/2004 US Edition 4. 5 Setting up the placement machine 165 frame, s ince this w ould deform t he machi ne frame. Æ Make sure that…

4 Setting up and commissioning User Manual SIPLACE HF Series
4.5 Setting up the placement machine Software Version SR.505.xx 05/2004 US Edition
164
4.5.4 Presetting the PCB transport height
Æ Push the forks of the fork-lift under the placement machine, as shown in Fig. 4.5 - 1.
4
Fig. 4.5 - 1 Contact surfaces - Forks parallel to the direction of PCB transport
(1) Contact surfaces for the forks of the fork-lift
WARNING
Please note the following points
before
you raise the placement machine in order to avoid irre-
versible damage to the machine:
– Open the forks just wide enough to position them between the two machine feet (the attach-
ment points are shown in Fig. 4.3 - 2
). The machine feet are 776 mm apart. NEVER increase
the distance between the forks so that the machine is lifted on the side parts of the machine

User Manual SIPLACE HF Series 4 Setting up and commissioning
Software Version SR.505.xx 05/2004 US Edition 4.5 Setting up the placement machine
165
frame, since this would deform the machine frame.
Æ Make sure that the forks are evenly loaded when you lift the machine. A firm support between
the forks and placement machine will prevent the machine tilting when it is raised. This will also
prevent a one-sided load on the machine feet, which would deform the fixing of the machine
feet. We recommend that a second person watch the machine as it is raised, and make sure
that the machine does not tip to one side when lifted with the fork-lift.
Æ With the fork-lift, raise the machine approximately 35 cm. This will avoid any risk of injuring your
feet if you lower the machine feet accidentally.
The placement machine stands on 6 feet.
– 4 machine feet (item 1 in Fig. 4.5 - 2
)
– 2 "HS50" machine feet (item 2 in Fig. 4.5 - 2
) with 2 spacers (items 3 and 4 in Fig. 4.5 - 2)
for adjusting the height, if necessary.

4 Setting up and commissioning User Manual SIPLACE HF Series
4.5 Setting up the placement machine Software Version SR.505.xx 05/2004 US Edition
166
4
Fig. 4.5 - 2 Placement machine feet
4
(1) Machine foot
(2) "HS50" machine foot
(3) Spacer on the pneumatic unit side
(4) Spacer on the power supply unit side
(5) Threaded hole for the "HS50" machine foot
(T) Direction of PCB transport
(P) Pneumatic unit
(S) Power supply unit