00193922-01.pdf - 第218页
5 Tasks on the machine User Manual SIPLACE HF Series 5.4 Setting up the feeders Software Version SR.505.xx 05/2004 US Edition 218 5.4.1 Prep aring the co mponent fe eder t able and feeder for set-u p Æ Se lect the l ocat…

User Manual SIPLACE HF Series 5 Tasks on the machine
Software Version SR.505.xx 05/2004 US Edition 5.4 Setting up the feeders
217
5.4 Setting up the feeders
5
Fig. 5.4 - 1 Component feeder table with 15 locations for feeders
(1) Feeder
(2) Centering pin
(3) Centering ball
(4) Component feeder table
(5) Feeder connecting cable

5 Tasks on the machine User Manual SIPLACE HF Series
5.4 Setting up the feeders Software Version SR.505.xx 05/2004 US Edition
218
5.4.1 Preparing the component feeder table and feeder for set-up
Æ Select the location at which you wish to place the feeder.
Æ Move the placement head to the waiting position and press the emergency stop button.
Æ Open the protective cover.
Æ Clean the contact surface for the feeder and the contact surface for the feeder on the compo-
nent feeder table.
5.4.2 Inserting the feeder
Æ
First place the front of the feeder (item 1), i.e. the side with the slotted foot, onto the component
feeder table (item 4) so that the centering pin (item 2) on the component feeder table slides
into the slot in the feeder foot.
Æ Then lower the back of the feeder until the centering ball (item 3) disappears into the hole in
the feeder.
Æ Make sure that the feeders are placed correctly on the component feeder table to suit their
width (see Fig. 5.4 - 2
).
Æ Check that the feeder is firmly seated on the component feeder table.
Æ Connect the feeder plug (item 5) to the socket beneath the location.
PLEASE NOTE 5
When you connect the feeder, make sure that you use the right socket for the location since
the feeder receives the control pulse via this socket. The feeder may not work correctly if it
is not connected to the right socket. The user manual for the feeder used will contain de-
tailed information on the assignment of plugs to sockets. 5
Æ Close the protective covers.
Æ Release the emergency stop button.
Æ Switch the control on again by pressing the start button.
Æ Carry out a refill check if necessary.
Æ Continue placement.

User Manual SIPLACE HF Series 5 Tasks on the machine
Software Version SR.505.xx 05/2004 US Edition 5.4 Setting up the feeders
219
Fig. 5.4 - 2 Inserting 30 or 45 mm wide feeders on the component feeder table
(1) Feeder, 30 mm wide
(2) Feeder, 45 mm wide
(3) Feeder, 30 mm wide