00193922-01.pdf - 第340页

7 Station extensions User Manual SIPLACE HF Series 7.16 Vacuum pum p Software Version SR.505.xx 05/2004 US Edition 340

100%1 / 358
User Manual SIPLACE HF Series 7 Station extensions
Software Version SR.505.xx 05/2004 US Edition 7.16 Vacuum pump
339
7.16 Vacuum pump
Every Collect&Place head has a separate vacuum generator that supplies the holding and place-
ment circuit with the vacuum that it needs. The vacuum generator works on the Venturi principle.
The HF/3 machine's compressed air consumption is approximately 550 Nl/min, which means that
the compressed air supply must be dimensioned accordingly. If the owner does not have sufficient
capacity locally, the associated investment costs would be high, so we supply a vacuum pump that
will provide the necessary vacuum.
Other advantages of using the vacuum pump are:
It roughly halves the machine's compressed air consumption.
It reduces the input pressure.
The placement machine can be easily integrated into existing lines.
The ongoing operating costs reduce according to the energy costs.
The vacuum pump is maintenance-free and 100% oil-free. They have sufficient capacity to supply
the holding circuits of the Collect&Place heads.
Compressed air
consumption
without
vacuum
pump
Compressed air
consumption
with
vacuum
pump
Compressed air consumption
with 4 tape cutters and in re-
lation to the placement head
configuration
HF placement machine
C&P / TH
C&P / C&P
HF/3 placement machine
C&P / C&P / TH
C&P / C&P / C&P
350 l/min.
450 l/min.
550 l/min.
700 l/min.
250 l/min.
200 l/min.
350 l/min.
300 l/min.
7 Station extensions User Manual SIPLACE HF Series
7.16 Vacuum pump Software Version SR.505.xx 05/2004 US Edition
340
User Manual SIPLACE HF Series Index
05/2004 US Edition
341
Index
"HS50" machine foot 167, 168, 202
12 mm S feeder for capacitors based on powdered
metal
model C/D
239
model E
240
12/16 mm S feeder
238
12-segment Collect&Place head
24 x 24 component vision camera
99
angular accuracy
102
checking and self-learning functions
100
component range
102
component specification
102
description
99
description of the functions
100
DP axis
101
forced air valve
98
intermediate distributor board
99
nozzle types
102
set-down force
102
silencer
98
star axis
101
star drive - DR motor
99
star with 12 sleeves, star axis
98
technical data
102
turning station, DP axis
98
vacuum generator
98
valve adjustment drive
99
X/Y accuracy
102
Z axis
101
Z axis motor
99
24/32 mm S feeder
241
3 x 8 mm S feeder
236
3x8mm S feeder for 0201/0402 CO
237
44 mm S feeder
242
56 mm S feeder
243
6-segment Collect&Place head
39 x 39 component vision camera
104
angular accuracy
107
checking and self-learning functions
105
component range
107
component specification
107
description
105
description of the functions
105
DP axis
106
forced air valve
103
intermediate distributor board
104
nozzle types
107
set-down force
107
silencer
103
star axis
106
star drive - DR motor
104
star with 6 sleeves - star axis
103
technical data
107
turning station, DP axis
103
vacuum generator
103
valve adjustment drive
104
X/Y accuracy
107
Z axis
106
Z axis motor
104
72 mm S feeder
244
8 mm S II feeder
235
88 mm S feeder
245
A
abbreviations 23
adapting the component trolley to the PCB transport
height
tools and equipment
205
warning instructions
205
ambient factors, permitted
92
angle for the cable gland
112, 159
angular accuracy
90
assembly positions for the stationary P&P compo-
nent vision camera (type 22) 50 x 40
132
assembly trough
138
atmospheric humidity
92
authorized accessories
28
authorized employees.
84
automatic circuit breaker F1
76, 79
automatic width adjustment on the dual conveyor
306
avoiding track errors
222
axis unit
69, 144
axis unit (HF)
188