3OM-1208-011_w.pdf - 第200页

5-13 AIVEDT -ID (15) T otal handling errors/T otal components Shown are the total number of pickup errors, the total number of components to be picked up, and the percentage of picked components per total number of picku…

100%1 / 345
5-12
AIVEDT-ID
Others
Shown is the period of time during which the X/Y beam takes
actions before component placement, the X/Y table returns after
component placement, etc.
Stop time
Shown is the period of time during which component placement
operation was interrupted for component replenishment, etc.
Error stop
Error alarm
Shown is the period of time during which an alarm (light tower
ON) is issued.
Recovery
Shown is the time between error cancellation and restart of
machine operation.
Feeder Reload
Shown is the time during which components were replenished.
Others
Shown is the period of time during which the machine has performed
the setup, program change, idling operations, etc.
(12) Maintenance time
Shown is the period of time during which the [SETUP] button on the
main menu bar is pressed.
(13) Warm-up run (Test Mode) time
The running time is counted when the machine is operated under the
following condition.
"Test Mode" is enabled in the "OPERATION MODE" window
.
The "PCB Transfer Dsbl." check box is ticked.
(State in which no PCB is put in and out)
(14) Test mode time
Shown is the period of time during which test run was performed
according to the test mode parameters.
0606-009
2.1 Machine Performance Data
5-13
AIVEDT-ID
(15) Total handling errors/Total components
Shown are the total number of pickup errors, the total number of
components to be picked up, and the percentage of picked components
per total number of pickup errors.
A: comp.missing (% of Total handling errors)
Shown are the number of component missing errors detected by the
linear measure detection sensor and the percentage of component
missing errors per total number of pickup errors.
B: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected in the
recognition process and the percentage of component missing errors per
total number of pickup errors.
C: comp. vertical (% of Total handling errors)
Shown are the number of vertical component errors detected by
the linear measure detection sensor and the percentage of vertical
component errors per total number of pickup errors.
D: comp. recog. (% of Total handling errors)
Shown are the number of errors detected in the recognition process and
the percentage of errors per total number of pickup errors.
E: comp. thick (% of Total handling errors)
Shown is the percentage of component thickness errors detected by the
linear measure detection sensor per total number of pickup errors.
F: pick-up diff (% of Total handling errors)
Shown are the number of pickup difference errors detected in the
recognition process and the percentage of the errors per total number of
pickup errors.
G: component posture (% of Total handling errors)
Shown are the number of reversed component and polarity judgment
errors detected in the recognition process and the percentage of the
errors per total number of pickup errors.
Total handling errors
Shown is the total number of component handling errors.
0606-009
2.1 Machine Performance Data
5-14
AIVEDT-ID
Zones 1 through 5
1point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the first fiducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
2point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the second fiducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
3point errors (% of T
otal PEC recog. errors)
Shown are the total number of errors detected on the third fiducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
Local fiducial errors (% of
Total PEC recog. errors)
Shown are the total number of recognition errors in each individual
components and the percentage of the detected errors per total number
of all errors detected by the PEC recognition function.
Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition
function.
The number of errors detected by the global PEC recognition function
and the total number of errors detected by the BBR recognition function
are displayed.
0606-009
2.1 Machine Performance Data