5-33 AIVEDT -ID (5) C: Comp. V ertical Each text box shows the total number of vertical component errors detected by the linear measure detection sensor for each individual feeders. (6) D: Comp. Recog. Each text box show…

5-32
AIVEDT-ID
0606-009
3.3 Handling Errors Per Feeder
3.3 Handling Errors Per Feeder
When the "Handling Error Per Feeder" tab is pressed in the "Pattern Program
Management Data" window, the following tab sheet appears inside the
window.
Fig. 3E15 "Handling Errors Per Feeder" Tab Sheet
Note
The displayed tab sheet will look different, depending on which option is
selected.
The corresponding tab sheet enables the operator to view the handling errors
on each individual feeders of the production model.
The "Handling Errors Per Feeder" tab sheet is divided further into several
tabs and each tab sheet shows the handling errors per feeder on each
individual feeder bases.
When a tab is pressed, the corresponding tab sheet appears, indicating that
the related feeder base is selected.
(1) Feeder No. (Actual Fdr No.)
Shown are the feeder Nos.
(2) Total Components
Each text box shows the total number of picked components (number of
pickup actions) for each individual feeders.
(3) A: Comp. Missing
Each text box shows the total number of missing components detected
by the linear measure detection sensor for each individual feeders.
(4) B: Comp. Missing
Each text box shows the total number of missing components detected
through recognition operation for each individual feeders.

5-33
AIVEDT-ID
(5) C: Comp. Vertical
Each text box shows the total number of vertical component errors
detected by the linear measure detection sensor for each individual
feeders.
(6) D: Comp. Recog.
Each text box shows the total number of errors detected through
recognition operation for each individual feeders.
(7) E: Comp. Thick
Each text box shows the total number of errors in component thickness
detected by the linear measure detection sensor for each individual
feeders.
(8) F: Pick-up Dif
f
Each text box shows the total number of pickup difference errors
detected in the recognition process for each individual feeders.
(9)
G: Comp. Posture
Each text box shows the total number of reversed component and
polarity judgment errors detected in the recognition process for each
individual feeders.
(10) Total Errors
Each text box shows the total number of errors detected in (3) through
(9).
(11)
Rate of Error (%)
Each text box shows the percentage of the total number of errors per the
number of picked components.
(12) Shrtg. of Comp.
Each text box shows the total number of the detected component
shortage errors for each individual feeders.
0606-009
3.3 Handling Errors Per Feeder

5-34
AIVEDT-ID
(13) Component ID
Each text box shows the component IDs for each individual feeders.
(14) Type
Each text box shows the component type.
(15) Width (mm)
Each text box shows the component width.
Note
When one of the above buttons is pressed, the feeder No. with the biggest
parameter under the selected button is displayed in the first line and feeder
Nos. having the subsequent (second, third, fourth, ...) biggest parameters
follow.
That is, parameters are re-arranged in order of error counts, making it easy
to analyze and improve production rate.
When the [Feeder No.] button is pressed, the feeder Nos. are re-arranged
in their initial order (order of slot Nos.).
0606-009
3.3 Handling Errors Per Feeder