3OM-1208-011_w.pdf - 第268页
6-35 AIVEDT -ID 2.1.16 Nozzle Level A Offset When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the "Noz. Level A" tab is selected, the following tab sheet appears. Fig. 3…

6-34
AIVEDT-ID
2.1.15 Head Rotation Correction Offset
When the "Head [2/2]" tab is pressed in the "Device Offset" tab sheet and the
"Hd. Rotate Corr. Head #1" tab is selected, the following tab sheet appears.
Note
A similar tab sheet will appear with the [Hd. Rotate Corr. Head #2], the
[Hd. Rotate Corr. Head #3], or the [Hd. Rotate Corr. Head #4] tab.
Fig. 3F32 "Hd. Rotate Corr. Head #1" Tab Sheet
Nozzles #1 through #12
DD An
gles 0 (+) to 330 (+) and 0 (-) to 330 (-), X [mm], Y [mm]
(Not
Available)
2.1 Device Offset Data
0606-009

6-35
AIVEDT-ID
2.1.16 Nozzle Level A Offset
When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the
"Noz. Level A" tab is selected, the following tab sheet appears.
Fig. 3F33 "Noz. Level A" Tab Sheet
Nozzle 1 through 12
Head #1, Head #2, Head #3, and Head #4
L (Height) [mm]
Each parameter indicates the offset of the bottom level of the normal
nozzles on each individual heads.
Measure each nozzle bottom level with a linear measure while the
nozzle U/D axis is zeroed and save the difference between the level and
the master nozzle level offset.
Note
These parameters are calculated using the formula "Nozzle Level Offset =
Master Nozzle Level - Measured Value of Normal Nozzle Level".
2.1 Device Offset Data
0606-009

6-36
AIVEDT-ID
2.1.17 Nozzle Position Offset
When the "Nozzle" tab is pressed in the "Device Offset" tab sheet and the
"Nozzle Position" tab is selected, the following tab sheet appears.
Fig. 3F34 "Nozzle Position" Tab Sheet
2.1 Device Offset Data
0606-009