3OM-1208-011_w.pdf - 第257页
6-24 AIVEDT -ID Head 1, Head 2, Head 3, and Head 4 X (Horizontal), Y (V ertical) [mm] The set parameters are used to adjust the deviations in the design value betwe en the head rotational center and the center of t he PE…

6-23
AIVEDT-ID
2.1.8 Head Rotational Center Offset
When the "Head [1/2]" tab is pressed in the "Device Offset" tab sheet and the
"Hd Center" tab is selected, the following tab sheet appears.
Fig. 3F22 "Head Center" Tab Sheet
0606-009
2.1 Device Offset Data

6-24
AIVEDT-ID
Head 1, Head 2, Head 3, and Head 4
X (Horizontal), Y (Vertical) [mm]
The set parameters are used to adjust the deviations in the design value
betwe
en the head rotational center and the center of the PEC recognition
camera.
Xm (+)
Ym (+)
Xm-Ym : Machine Reference
Coordinate System
Center of PEC Recognition Camera
Center of PEC Recognition Camera
Head Rotational Center
Head Rotational Center
Pm. Machine Reference
Coordinate Origin
Fig. 3F23
0606-009
2.1 Device Offset Data

6-25
AIVEDT-ID
2.1.9 Head Rotational Angle Axis Offset
When the "Head [1/2]" tab is pressed in the "Device Offset" tab sheet and the
"Hd Rotate Axis" tab is selected, the following tab sheet appears.
Fig. 3F24 "Head Rotate Axis" Tab Sheet
0606-009
2.1 Device Offset Data