3OM-1208-011_w.pdf - 第212页

5-25 AIVEDT -ID 3.1 Pattern Program Product History When the "Pattern Program Product History" tab is pressed in the "Pattern Program management Data" window , the following tab sheet appears inside t…

100%1 / 345
5-24
AIVEDT-ID
0606-009
[2] Tabs and Tab Sheets
The "Pattern Program Management Data" window is provided with the
following three tabs. When each tab is pressed, the corresponding tab
sheet appears inside the window.
Table 3E4
Tabs Description
Pattern Program Product
History
The corresponding tab sheet enables the operator to check the date
and time logs that show when the use of the selected pattern
program was started or ended.
Machine Performance Data
The corresponding tab sheet enables the operator to view the listed
data such as "PCB counter", "Product PCB", "Passed PCB", "Product
PCB (BBR) (option)", "T
otal components", "Total handling errors",
"Rate of handling errors (%)", "Shortage of component", "PCB
process time", "Power on time", "Maintenance time", "Test mode
time", "Total handling errors/T
otal components", etc.
Handling Errors Per Feede
r Displayed is a list of "Total Components", "Number of Errors
(classified by error types)", "Total Errors", "Rate of Error (%)",
"Shrtg. of Comp.", "Component ID.", "Type", and "Width (mm)" for
each feeder No. (actual feeder No.).
3. Pattern Program Management Data
5-25
AIVEDT-ID
3.1 Pattern Program Product History
When the "Pattern Program Product History" tab is pressed in the "Pattern
Program management Data" window, the following tab sheet appears inside
the window.
Fig. 3E13 "Pattern Program Product History" Tab Sheet
Up to 10 records (logs that show the number of times specified as current
pattern program) are displayed for each individual pattern programs.
The start and end date & time records (logs) are also displayed for the
selected pattern program.
When there are more than 10 logs, the older ones are deleted one by one.
3.1 Pattern Program Product History
0606-009
5-26
AIVEDT-ID
3.2 Machine Performance Data
When the "Machine Performance Data" tab is pressed in the "Pattern
Program Management Data" window, the following tab sheet appears inside
the window.
Fig. 3E14 "Machine Performance Data" Tab Sheet
A list of management data (the counted numbers (total counts included)
related to "Stage #1" and "Stage #2" for the current program (model)) is
displayed for each pattern program.
(1) PCB counter
Shown is the number of produced PCBs.
Counting is implemented when the X/Y table is zeroed after component
placement operation (when a PCB is fi
nished).
Note
When a particular pattern program is set several times as current one, the
sum total is computed.
(2) Product PCB
The number of produced unit PCBs on multi-unit PCB is summed up.
Counting is implemented when the X/Y beam is zeroed after component
placement operation (when a unit is finished).
When the bad board reject (BBR) function (option) is used, defective
unit PCBs are excluded.
3.2 Machine Performance Data