3OM-1208-011_w.pdf - 第89页

3-2 AIVEDT -ID (A01_02) PCB size X (Horizontal), Y (V ertical), and T (thickness) [mm] Set the dimensions of the PCB to be produced. T (Thickness) Y (V ertical) X (Horizontal) PCB PCB Flow Direction Fig. 3C1 When the PCB…

100%1 / 345
3-1
AIVEDT-ID
0606-009
1. Pattern Program
1. Pattern Program
1.1 Pattern Program Name
To save a pattern program, it is required to give a name to the program.
Up to 32 characters (alphanumerics and marks) can be used.
1.2 Operation Data
The contents of this instruction manual is based on
"
Front Right
"
(placement
coordinate reference point).
1.2.1 (A01) PCB Data
(A01_01)
Comment 1 and Comment 2
Comments on the pattern program can be specified in these text boxes.
Up to 32 characters (alphanumerics and marks) can be used.
Note
The performance of the machine is not affected by these comments. In
other words, it has nothing to do with or without these comments.
3-2
AIVEDT-ID
(A01_02)
PCB size
X (Horizontal), Y (Vertical), and T (thickness) [mm]
Set the dimensions of the PCB to be produced.
T (Thickness)
Y (Vertical)
X (Horizontal)
PCB
PCB Flow Direction
Fig. 3C1
When the PCB has a cutout, the following dimensions must be entered.
T (Thickness)
Y (Vertical)
X (Horizontal)
PCB
PCB Flow Direction
Fig. 3C2
Data Input Range
X:
50 to 460
Y
:
50 to 460
T:
0.5 to 5.0
Note
(a) Be sure to set a correct parameter in the "X (Horizontal)" text
box because the set parameter is used to automatically correct the
placement position when a parameter is selected in the "PCB locate
method" text box in the "PCB transfer Mode Setup" tab sheet.
(b) The set parameter in the "Y (Horizontal)" text box must be used as a
target width for the conveyor width automatic adjustment operation.
(c) "T (Thickness)" is used as a target value for the backup table
ascending position when a PCB is clamped by the clamp plates and
positioned.
0606-009
1.2 Operation Data
3-3
AIVEDT-ID
(A01_03)
PCB origin offset
X (Horizontal), Y (Vertical) [mm]
Set the offset values to correct the difference between the placement
coordinate reference (N
0
) and the PCB origin (P
0
).
"
Plus
"
or
"
Minus
"
can be set in both X and Y coordinates in the
direction of the correction.
Placement Coordinate Reference Point :
For Front Right
Y
PCB Origin(P0)
PCB
X
Placement Coordinate Reference (N0)
PCB Origin(P0)
Y
X
Placement Coordinate Reference (N0)
X
Y
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Y
X
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Placement Coordinate Reference Point :
For Rear Left
Placement Coordinate Reference Point :
For Front Left
Placement Coordinate Reference Point :
For Rear Right
PCB
+
+
+
+
+
+
+
+
Fig. 3C3 Example of
"
+
"
(Plus) Direction for Correction
0606-009
1.2 Operation Data