3OM-1208-011_w.pdf - 第232页

6-A AIVEDT -ID 0606-009 Chapter 6 System Setting This chapter describes the functions and operations related to the machine system data, the nozzle data, etc. • Menus for System Setting • Machine System • Nozzle Data • M…

100%1 / 345
5-44
AIVEDT-ID
(6) E: Comp. Thick
Each text box shows the number of errors in component thickness
detected by the linear measure detection sensor for each individual
nozzles.
(7) F: Pick-up Diff
Each text box shows the number of pickup difference errors detected in
the recognition process for each individual nozzles.
(8)
G: Comp. Posture
Each text box shows the number of reversed component and polarity
judgment errors detected in the recognition process for each individual
nozzles.
(9) Nozzle Message Rate (Total Errors/Total Noz. Usage)
Each text box shows the rate of pickup errors (the number of pickup
errors per number of picked component) for each individual nozzles.
Note
When one of the above buttons is pressed, the feeder No. with the biggest
parameter under the selected button is displayed in the first line and feeder
Nos. having the subsequent (second, third, fourth, ...) biggest parameters
follow. That is, parameters are re-arranged in order of error counts, making
it easy to analyze and improve production rate.
When the [Nozzle] button is pressed, the nozzle Nos. are re-arranged in
their initial order (order of nozzle Nos.).
0606-009
4.5 Nozzle Message Rate
6-A
AIVEDT-ID
0606-009
Chapter 6
System Setting
This chapter describes the functions and operations
related to the machine system data, the nozzle data, etc.
Menus for System Setting
Machine System
Nozzle Data
Machine Setup
Password Setting
Date &
T
ime Setting
Network Setting
Operation Screen
Adjustment
6-B
AIVEDT-ID
0606-009