YSI_Prog_E.pdf - 第148页

3-25 3 Step screen T est range All : T ests all steps. Only Piece of Board : T ests steps in individual boards of the selected multi-board panel No. Only Selected V iew : T ests steps in the selected view . Only Selected…

100%1 / 226
3-24
3
Step screen
2.4 Step test
It is necessary to perform tuning for all parameters in order that the test result for created steps is correct. To
check the step test result, use the buttons in the "Tuning" tab in the lower right of the "Step" screen - "Tuning"
tab. To review settings, see Chapter 4, "Inspection status", in this manual.
2.4.1 Multi-test
The multi-test function is used to perform a step test under set conditions. For example, the "Lib Parts Name" is
specified at such times as when creating a new library, an inspection is performed for all of the same libraries
on the board, and parameters are tuned based on the inspection result.
1
Press the [Multi] button at the "Tuning" tab.
A "Multi-test Result" window appears at the top of the screen.
"Multi-test Result" window
[Condition] button
[Execute] button
"Multi-test Result" window
24329-P6-00
2
Press the [Condition] button and set the inspection conditions.
By pressing the [Condition] button, a "Test Condition Setting" dialog box appears. Select each item from
the respective drop-down list boxes, and press the [OK] button when setting is complete.
"Test Condition Setting" dialog box
[OK] button
24330-P6-00
Test Subject
Step : Tests all steps.
Inspection Status : Tests steps for the selected inspection status.
Parts : Tests steps for the selected parts.
NG Reason : Tests steps with selected NG reason.
Test condition
All : Tests all steps.
Same Lib Parts Name : Tests steps with same selected Lib parts name.
Same Parts Name : Tests steps with same selected parts name.
Same Ref. No. : Tests steps with same selected Ref. No.
3-25
3
Step screen
Test range
All : Tests all steps.
Only Piece of Board : Tests steps in individual boards of the selected multi-board panel No.
Only Selected View : Tests steps in the selected view.
Only Selected Parts : Tests steps for the selected part.
Test Board Side (YSi-X)
Performs a test based on the "A/B Side" setting in the basic parameters.
Side A : Tests only those steps for which "A/B Side" is set to "Side A".
Side B : Tests only those steps for which "A/B Side" is set to "Side B".
Both : Tests all steps, regardless of the "A/B Side" setting.
Image List Test
Skip : Tests only standard images, and does not test images in the image list.
All : Tests standard images and images in the image list.
Exec OK Parts : Tests standard images and images in the OK image list.
Exec NG Parts : Tests images in the NG image list.
3
Press the [Execute] button to perform a multi-test.
4
Check the test results.
A list of test results appears when the test is complete, allowing the test results and detection values for
each step to be referenced. Steps with NG result appear in red.
Multi-test results example
Ref. No. unit display
[Close] button
Results list
NG step
[Analysis] button
Changes the display.
NG Parts Count
NG Steps Count
24331-P6-00
3-26
3
Step screen
Changes the display.
Display by Ref. No.
Ref. No. unit (part unit) test results are displayed in the left side list of the inspection list. By selecting parts from
the list, the selected row is highlighted in blue, and the step test result for the applicable part is displayed in the
right side list of the inspection list. Select a step and check the step position and parameters.
Display by Step:
Displays the test results for all tested steps. Select a step and check the step position and parameters.
NG Parts Count
Displays the number of parts for which the test result is NG.
NG Steps Count
Displays the number of steps for which the test result is NG.
[Analysis] button
By selecting a display item, the test result for the relevant item is displayed in a graph. Refer to this when setting
parameters for data tuning.
5
Press the [Close] button to exit the multi-test.