YSI_Prog_E.pdf - 第52页
1-17 1 asic operation 1. [NG Reason] button Changes the NG reason for NG steps. 2. [All NG] button Judges NG for all steps judged to be NG b y the inspection machine. 1.5.6 "Height Measure" screen T his scree…

1-16
1
asic operation
1.5.4 "Bad Mark" screen
This screen allows you to display the bad mark recognition results for each inspection. Recognition results can
be checked by selecting the bad mark type from a drop-down list.
[Auto] – [Bad Mark] screen
Bad mark type
Recognition results
24116-P6-00
1.5.5 "Judge" screen
By enabling the "Second Judge" function in the machine settings, the (Judge) tab is added. This screen displays
board NG results the moment inspection is complete, or after board unloading. Select OK or NG for NG results
displayed in the NG judgment list. Inspection of the next board is performed while performing OK/NG judg-
ment, and therefore inspection of the next board will not be complete until judgment of all NG items is
complete.
TIP
The timing at which results are displayed in the "Judge" screen can be set in "Second Judge Setting"
→
"Judgment
timing" in the machine settings.
[Auto] – [Judge] screen
Displays the inspection result.
Inspection image
OK image
1
2
24117-P6-00

1-17
1
asic operation
1. [NG Reason] button
Changes the NG reason for NG steps.
2. [All NG] button
Judges NG for all steps judged to be NG by the inspection machine.
1.5.6 "Height Measure" screen
This screen exists when the machine is equipped with a laser height sensor. Displays the measurement result if
performing height measurement inspection.
[Auto] – [Height Measure] screen
24118-P6-00

1-18
1
asic operation
1.5.7 "Conveyor" screen
Displays the current conveyor status.
[Auto] – [Conveyor] screen
YSi-12, YSi-X
YSi-12
YSi-X
24119-P6-00
Item
Applicable model Status
Upstream
side
Busy Out YSi-12 YSi-X
Lights up green when outputting a board transfer permission signal to
the upstream machine.
BA In YSi-12 YSi-X
Lights up green when inputting a board unloading request signal from
the upstream machine.
Ent. Upper – YSi-X Lights up green when the entrance shutter is open.
Ent. Lower – YSi-X Lights up green when the exit shutter is closed.
Downstream
side
Busy In YSi-12 YSi-X
Lights up green when inputting a board transfer permission signal from
the downstream machine.
BA Out YSi-12 YSi-X
Lights up green when outputting a board unloading request signal from
the downstream machine.
Exit Upper – YSi-X Lights up green when the entrance shutter is open.
Exit Lower – YSi-X Lights up green when the exit shutter is closed.
Conveyor
Push Up YSi-12 YSi-X Lights up green when the push up is up.
Entrance,
Inspection, Exit
YSi-12 YSi-X Lights up green when the board is present at each position.
Inspection
result
Result OK YSi-12 YSi-X Lights up green when the board inspection result is "OK".
Result NG YSi-12 YSi-X Lights up green when the board inspection result is "NG".