YSI_Prog_E.pdf - 第41页
1-6 1 asic operation 1.4.3 "Bad Mark" screen T his screen allows you to set bad marks in order to use the bad mark function. T he bad mark function inv olves affixing a mark (bad mark) to a set location on th…

1-5
1
asic operation
1.4.2 "Fiducial" screen
This screen allows setting fiducial marks to use the fiducial function. Based on recognition results of the
fiducial marks on the board under inspection, the fiducial function corrects local distortion or warps on the
board that may occur from errors in machining the board outline or locate pin holes, or board clamping
mechanism fluctuations.
[Data Edit] – [Fiducial] screen
1
2
3
4
7
8
9
10
12 13 14
Mark list
Mark type list
11
5
6
18 19 2016
17
Basic parameter
15
24105-P9-00
Item/button name Function
1 Board/Block/Local The unit for enabling the fiducial function can be selected from board, block, or local.
2 Trace Moves the camera to the mark XY coordinates selected in the mark list.
3 Teach The center of the recognized mark is registered as the fiducial mark position coordinates.
4 Find Searches for and replaces items registered in the block or local mark list.
5 Zoom
+ : Enlarges the fiducial mark image.
- : Reduces the fiducial mark image.
The image can also be enlarged and reduced by rotating the mouse wheel.
6 Change lighting
Changes the fiducial image lighting. Select the lighting that results in the clearest image
from U, H, M, and L.
7 Set Mark Registers the selected mark in the library.
8 Library Pastes the mark registered in the library.
9 Light List
Displays a list with the mark image illuminated under each lighting, allowing the operator
to select the most suitable lighting from the list.
10 Measure
By dragging the mouse to enclose the identified mark, parameters are measured
automatically based on the "Algorithm Type" set in the basic parameters.
11 Template
Saves template data for pattern matching. This button becomes active when pattern
matching is selected at "A. Algorithm Type" in the basic parameters.
12 Measure Measures the distance on the fiducial image.
13 Detected Displays the detected range based on the set threshold value conditions in red.
14 Insp img Displays the inspection image with the lighting selected in the lighting list.
15 Image List Selects fiducial mark images saved to the image list.
16 0.1mm
Pressing this button changes the pitch for the camera to move when the arrow buttons
on the scroll bars are pressed. (0.01mm, 0.100mm, 0.500mm, 5.000m)
17 Result display Displays the result of the fiducial mark recognition test.
18 Test Perform a fiducial mark recognition test.
19 End Test Ends a fiducial mark recognition test.
20 Threshold slide bar Displays and changes the detection threshold value.

1-6
1
asic operation
1.4.3 "Bad Mark" screen
This screen allows you to set bad marks in order to use the bad mark function. The bad mark function involves
affixing a mark (bad mark) to a set location on the board in order to ensure that inspection is not performed
when the mark is recognized by the inspection machine.
[Data Edit] - [Bad Mark] screen
1
9
11 12
10
13
14
Basic parameter
Mark list
2
3
4
7
8
5
6
24106-P6-00
Item/button name Function
1 Board/Block/Local The unit for enabling the bad mark function can be selected from board, block, or local.
2 Trace Moves the camera to the mark XY coordinates selected in the mark list.
3 Teach The center of the recognized mark is registered as the bad mark position coordinates.
4 Find Searches for and replaces items registered in the block or local mark list.
5 Zoom
+ : Enlarges the bad mark image.
- : Reduces the bad mark image.
The image can also be enlarged and reduced by rotating the mouse wheel.
6 Change lighting
Changes the bad mark image lighting. Select the lighting that results in the clearest
image from U, H, M, and L.
7 Set Mark Registers the selected mark in the library.
8 Library Pastes the mark registered in the library.
9 Light List
Displays a list with the mark image illuminated under each lighting, allowing the operator
to select the most suitable lighting from the list.
10 Thresh
Sets the threshold value used for mark recognition. By pressing this button, a "Bad mark
threshold value setting" screen appears, allowing the user to set the threshold value
when marks are detected and when not detected.
11 Insp img
Displays the view image selected in the view list. The view image can be changed even
by selecting the board image view.
12 0.1mm
Pressing this button changes the pitch for the camera to move when the arrow buttons
on the scroll bars are pressed. (0.01mm, 0.100mm, 0.500mm, 5.000m)
13 Result display Displays the result of the bad mark recognition test.
14 Test Performs the bad mark recognition test.

1-7
1
asic operation
1.4.4 "View" screen
This screen allows you to register inspection view coordinates, save view images, and edit views.
[Data Edit] - [View] screen
1
2
3
4
5
9819 20 21 22 23
15
16
17
18
10 1211
13
14
6
7
View radar
View list
View image
24107-P6-00
Item/button name Function
1 Add View* Adds a view at the lower right of the selected view.
2 Delete View* Deletes the selected view.
3 Copy View* Copies the selected view.
4 Trace
Displays the selected view image. The view image can be changed even by selecting the
board image view.
5 Teach* Registers the coordinates displayed in the view list.
6 Zoom
+ : Enlarges the view image.
- : Reduces the view image.
The image can also be enlarged and reduced by rotating the mouse wheel.
7 Change lighting Changes the view image lighting. Select the lighting from U, H, M, L, and X (YSi-X).
8 Display
Displays the image selected in the image list.
OK images : Displays a list of saved images when the image list [Save] or [OverWrite]
button is pressed.
NG images : Displays a list of view images for which auto inspection was unsuccessful.
* To save NG images, select "Installation Setting"
→
"Image Setting" in the machine
settings, and select "NG Image" for "Image Auto SAVE".
9 Save*
Saves all view images and mark images as OK images. After saving images, always
press the [Save] button in the button area to save the program.
10 Overwrite* Select images in the OK board image list, and then press this button to overwrite images.
11 Delete Deletes all images with the selected board ID.
12 Edt Step
The [Edit Step] button becomes valid when the (NG) tab is opened. By selecting the view
for which "0" is displayed in the existing images list, selecting applicable parts from the
displayed parts list, and then pressing this button, the "Step" screen appears, allowing
the first step for relevant parts to be selected.
13 Rotation Sets the angle to rotate the copied view when pasting it.
14 Paste View* Pastes the copied view.
15 Pitch Rep.* Creates multiple view copies in the XY directions.
16 Auto* Automatically creates views while taking the step frame positions and sizes into account.
17 Sort* Changes the view numbers so that the camera movement time becomes the shortest.
18 Tile* Creates views in a tile pattern to fill the entire board.
19 Step Disp Displays step frames on the selected view image.