KE2040Instruction Manual Ver2.01,REV04.2003.6.25.pdf - 第922页

14 − 38 14.6 Copl anarity Sensor (Opti onal) 14.6.1 Name of each part Figure 14.6.1 Expl anation of the device Setting the moni tor screen sw it ch W hen you turn on the system or oper ate it nor mally, set this switch t…

100%1 / 1491
14 37
14.5.3 Recycling the Used Battery
Contact your recycling or hazardous waste center for information on proper disposal
of the used battery. We accept your battery for return at cost to you.
WARNING
Do not dispose of battery or batteries in a fire. Batteries may
explode. Proper disposal of batteries is required. Refer to your local
codes for disposal requirements.
Do not open or mutilate the battery or batteries. Released electrolyte
is harmful to the skin and eyes. It may be toxic.
CAUTION
Do not discard the UPS or the UPS batteries in the trash. This
product contains sealed, local recycling or hazardous waste center.
14 38
14.6 Coplanarity Sensor (Optional)
14.6.1 Name of each part
Figure 14.6.1 Explanation of the device
Setting the monitor screen switch
When you turn on the system or operate it normally, set this switch to A.
The menu screen does not appear on the monitor.
14.6.2 Daily maintenance
Check to see if the filter unit (photo-transmitting window/photoreceptive window) gets
soiled. (Check that everyday.)
Clean the filter unit with dry cloth or gauze.
Figure 14.6.2 Coplanarity unit
CAUTION
Carefully check to see if the filter unit is not soiled. When necessary,
be sure to clean it. It may cause the system to malfunction.
Do not use any alcohol to clean the filter unit.
Coplanarity check
controller
Coplanarity check
sensor cable
Monitor screen switch
Coplanarity check controller
Coplanarity check sensor cable
Explanation of the monitor screen
switch
Side A: Main unit (standard) screen
Side B: Coplanarity check screen
(for maintenance)
Side A
Side B
Photoreceptive
window
Photo-transmitting
window
Where
to
clean
14 39
14.6.3 Parts list
Table 14.6.1 Parts list (for the coplanarity unit)
No. Part number Part name Remarks
1 E9675729000 Coplanarity check sensor cable
2 E9674729A00 Filter unit (for the photoreceptive side)
3 E9674729B00 Filter unit (for the photo-transmitting side)