User manual SIPLACE TX-Series 6 Station extensions From software version 713.0 Edition 01/2020 6.7 Stationary camera s 311 6.7.2 Component camera, st ationary P&P , type 33, 55 x 45, digita l Item no. 00588100-xx St …

100%1 / 346
6 Station extensions User manual SIPLACE TX-Series
6.7 Stationary cameras From software version 713.0 Edition 01/2020
310
6.7.1.2 Technical data
6
Component dimensions 0.2 mm x 0.2 mm up to 16 mm x 16 mm for single component
measurement
Component range 0402 to SO, PLCC, QFP, sockets, plugs, BGA, special components,
bare dies, flip-chips, shields
Min. lead pitch 0.25 mm
Min. lead width 0.1 mm
Min. ball pitch 0.14 mm
Min. ball diameter 0.08 mm
Field of vision 19.4 mm x 19.4 mm
Illumination type Front-illumination (6 levels, programmable as required)
User manual SIPLACE TX-Series 6 Station extensions
From software version 713.0 Edition 01/2020 6.7 Stationary cameras
311
6.7.2 Component camera, stationary P&P, type 33, 55 x 45, digital
Item no. 00588100-xx Stationary camera for the CPP head, type 33
6
Fig. 6.7 - 2 Structure for the stationary P&P component camera, type 33, 55 x 45, digital
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below
6.7.2.1 Safety instructions
6
(1)
(2)
WARNING
Risk of collisions!
When changing the placement head from a TwinStar/VHF to a SpeedStar, the SpeedStar
collides with the camera housing.
Dismantle the stationary component camera for the TwinStar.
When changing the placement head from a TwinStar to a MultiStar, the stationary
component camera is fitted in the bottom position.
6 Station extensions User manual SIPLACE TX-Series
6.8 IPC-Hermes-9852 From software version 713.0 Edition 01/2020
312
6.7.2.2 Technical data
6
6.8 IPC-Hermes-9852
IPC-HERMES-9852 is a communication protocol for SMT lines and can replace the IPC SMEMA
interface. This protocol allows you to transfer more information than previously via the IPC
SMEMA interface.
This could be, for example:
Unique board IDs
Barcodes
Conveyor speed,
Board length and width
Board thickness
Transport clearance height
All this information can be transmitted along the whole line without interruption.
For a detailed description, see the Administrator Manual IPC-HERMES-9852, item no.
[00198615-xx].
6
Component dimensions 0.5 mm x 0.5 mm to 55 mm x 45 mm
Component range 0402, MELF, SO, PLCC, QFP, electrolytic capacitors, BGA
Min. lead pitch 0.3 mm
Min. lead width 0.15 mm
Min. ball pitch 0.35 mm
Min. ball diameter 0.2 mm
Field of vision 65 mm x 50 mm
Illumination type Front-illumination (6 levels, programmable as required)