2 Operational safety User manual SIPLACE TX-Series 2.6 Residual voltages and discharge times in the placement machine From software version 713.0 Edition 01/2020 96 2 Fig. 2.6 - 1 Power supply unit, front view (1) Main s…

100%1 / 346
User manual SIPLACE TX-Series 2 Operational safety
From software version 713.0 Edition 01/2020 2.6 Residual voltages and discharge times in the placement machine
95
2
2.6.2 Energy state at mains plug
2
2
2.6.3 Placement machine switched off at the main switch, but still connected
2
CAUTION
Data loss!
To avoid losing data, assess the following criteria before switching off your placement ma-
chine - (apart from in emergencies):
Has the placement machine finished transmitting machine, setup and panel data?
Has the placement machine finished processing the PCB?
Has the placement machine completed the run-up phase?
DANGER
Danger from residual voltage at the mains plug
After disconnecting the mains plug of a placement machine, a residual voltage of up to 60
µC could still be present (in line with EN 60204-1). When combining the power supply con-
nections for multiple placement machines, this could cause a hazard.
DANGER
Lethal voltages!
Incorrect handling of this placement machine can therefore result in death or severe injury
or considerable damage to equipment.
The following components still carry potentially lethal voltages in the power supply unit,
even if the main power switch is switched off:
Mains connection terminals
L1, L2 and L3 of main switch S1
Service socket X98 (if present)
Safety cutoff (CSB) still live for 5 minutes after switching off the main switch.
The color of all individual wires, which still carry electricity, even if the main power
switch is switched off, is orange.
2 Operational safety User manual SIPLACE TX-Series
2.6 Residual voltages and discharge times in the placement machine From software version 713.0 Edition 01/2020
96
2
Fig. 2.6 - 1 Power supply unit, front view
(1) Main switch (S1)
(2) Service socket (if present)
(1)
(2)
User manual SIPLACE TX-Series 2 Operational safety
From software version 713.0 Edition 01/2020 2.6 Residual voltages and discharge times in the placement machine
97
2.6.4 Main switch switched off - placement machine disconnected from the mains
power supply
2
2.6.5 Compressed air conditions in the placement machine after switching off at
the main power switch
When the main switch is switched off or the mains supply to the placement machine fails, the elec-
trically-controlled main valves of the compressed air unit will close (item 1 in fig. 2.7 - 1
, page 99).
The pressure will drop to 0 MPa (0 bar) within 5 seconds. The components before the electrically-
controlled main valves will remain pressurized.
DANGER
Lethal voltages in the power supply unit!
The power supply unit has components (capacitors) which can still conduct potentially le-
thal voltages for approx. 5 minutes, even when the placement machine has been switched
off and the mains plug has been disconnected.
When working on the power supply, switch off the main switch, secure it to prevent
switching on again, disconnect the placement machine from the power network and
wait 5 minutes until the capacitors have discharged.
Test to check that there is no remaining voltage supply. See the procedure described
in the service manual.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine
owner's service engineers, who have been trained by ASM, may perform work on the
power supply and the safety cutoff (CBS).