00197182-04_AI_Prepare_Kit_SX12_de_en.pdf - 第77页
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 Prepare Kit 04/2017 4 Appendix 4.2 Description of Boards 77 Fig.34: Overview of Fuses ● Fuse 5x20mm T6.3A 400VDC [03133256‑xx] (replaced: [03078843-xx]) ● Micro f…

4 Appendix
4.2 Description of Boards
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2
Prepare Kit 04/2017
76
4.2 Description of Boards
4.2.1 Distribution and Fusing Assembly [03118286-xx]
Fig.33: Distribution and fusing assembly [03104070-01]

Assembly Instructions / Montageanleitung SIPLACE SX1/SX2
Prepare Kit 04/2017
4 Appendix
4.2 Description of Boards
77
Fig.34: Overview of Fuses
●
Fuse 5x20mm T6.3A 400VDC [03133256‑xx] (replaced: [03078843-xx])
●
Micro fuse 5x20 / T 10 A [03010627-xx]
Fuses [03104070-01]
Fuse Description
F1 27V DC MGCU 1
F2 27V DC MGCU 2
F3 27V DC MGCU 3
F4 24V DC Distributor
F5 27V DC IBASE PC
F6 27V DC 3D Coplan PC option
F7 24V DC Transport
F8 27V DC Gantry 1
F9 27V DC Gantry 2
F10 24V DC Internal – C (internal voltage CSB – emergency off)
F11 24V DC SSK_Ready
F12 24V DC Safety Supply
F14 42V DC Gantry cable 1 MHCU
F15 42V DC Gantry cable 2 MHCU
F16 42V DC Conveyor drive
F17 27V DC Fuse protection 27V/24V DCDC
F18 Spare
F19 160V DC Head axes gantry 1
F20 160V DC Head axes gantry 2
F21 Spare
F22 27V DC FCU 1
F23 27V DC FCU 2

4 Appendix
4.2 Description of Boards
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2
Prepare Kit 04/2017
78
Connector [03104070-01]
Con-
nector
Designation Terminal
X1 Ground connection "distribution and fusing assembly" From main ground terminal
XB1A Gantry 1 – 24V & signals To gantry cable G1
XB1B Gantry 2 – 24V & signals To gantry cable G2
X2 Diagnostic serial interface (Diagnose Info F&D) To IOCU2 X11 sector 2
X5 FCU 1/2 – 27V DC To FCU1(X111)/2 (X131)
XB5A GCU 1/2 supply To MGCU1 / 2
XB5B GCU3 To MGCU3
XB8A Gantry 1 – 160V DC To gantry cable G1 head
XB8B Gantry 2 – 160V DC To gantry cable G2 head
X24A Star Voltage – 160V From CSB
X24B Safety control signals to FDB – DC42V IN/OUT To CSB
X25 DC 42V IN From AC/DC converter
X26 DC 27V IN From AC/DC converter
XB2 Power Distributor & PC 3D-Sensor – 27V/24V/42V To distributor in sector 2
XB4 Transport To conveyor