Dismantling a Gantry Performing Calibration Gantry Modularity Portalmodular ität 115 4.2 Performing Calibration

100%1 / 120
Dismantling a Gantry
Final work on the machine
114 Gantry Modularity Portalmodularität
4.1 Final work on the machine
At location 2 only: fit the long end position buffer if the gantry has been removed. Use a torque
wrench to tighten to 14 Nm. Take a look at the buffer monitoring function! The safety switch for for
the buffer monitoring function must engage in the Schmersal switch.
Fit the keyboard and close the two side doors again.
Calibrate (see below).
Fit the trailing cable to the holder next to the GCU.
CAUTION
Check, stationary camera, nozzle changer
Check whether gantry 1 can move to location 2 unhindered and whether it can also reach
the table pickup position.
In certain configurations, you need to dismantle the stationary camera and the second noz-
zle changer row and then move the table from the outer to the inner position.
Dismantling a Gantry
Performing Calibration
Gantry Modularity Portalmodularität 115
4.2 Performing Calibration
Dismantling a Gantry
Performing Calibration Description and Connections on the GCU
116 Gantry Modularity Portalmodularität
4.2.1 Description and Connections on the GCU
GCU - front side