00198375-02_UM_OnBoardPCB-Inspection-R18-1_DE_EN.pdf - 第66页
5 Inspection Process at the Station 5.3 Handling of Bad Inspection Results 66 User Manual / Bedienungsanleitung Onboard PCB Inspection 06/2018 5.3.4 Error During Solder Paste Inspection If solder paste inspection errors …

5 Inspection Process at the Station
5.3 Handling of Bad Inspection Results
User Manual / Bedienungsanleitung Onboard PCB Inspection 06/2018 65
5.3.3 Offset Recognized
If components with offset are detected, the relevant error message will be shown.
► Click on the error message to perform troubleshooting.
ð The following view will be shown.
► Decide how you want to handle the error and perform one of the actions shown.
► Click on the image to open the following view. The relevant details will be shown.

5 Inspection Process at the Station
5.3 Handling of Bad Inspection Results
66 User Manual / Bedienungsanleitung Onboard PCB Inspection 06/2018
5.3.4 Error During Solder Paste Inspection
If solder paste inspection errors are detected, the relevant error message will be shown.
► Click on the error message to perform troubleshooting.
ð The following view will be shown.
► Decide how you want to handle the error and perform one of the actions shown.
► Doubleclick on the image to open the following view. The relevant details will be shown.

5 Inspection Process at the Station
5.3 Handling of Bad Inspection Results
User Manual / Bedienungsanleitung Onboard PCB Inspection 06/2018 67
5.3.5 Incomplete Description of SIPLACE Pro Inspection Area
► Select (1) from the toolbar and open the teaching menu (2)