Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 60 10 Corrected E rr ors 10.1 706.1 SP2 Station Software Station s oftware ver sion 706.1 SP2 contains all the err or corr ecti…

100%1 / 144
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
59
Fine adjustment of the pitch at the feeder
For feeder types < 12mm, the current pitch in the feeder has to be set to > 4mm to achieve the
same functionality as on the operator panel of the feeder and to avoid incorrect settings for smaller
pitches.
Fault-tolerant operation of the Twin Head
If Segment 1 has been deactivated or removed from the configuration, e.g. some single
placement positions might not be reachable because of the limited traveling range of Segment
2. The machine stops with a corresponding error message and the board cannot be finished.
No plausibility check will be performed in advance for a defined job or a board that enters the
machine.
Head calibration is not possible, if Segment 1 is deactivated or has been removed from the
configuration. If this is necessary, the functioning segment has to be installed on the position of
Segment 1.
No CAN communication with a segment that has been removed from the configuration.
No control of the Z-security for a segment that has been removed from the configuration.
A segment that has been removed from the configuration will not be actively secured, but will
generally be hold by the cylinder.The segment is held high enough, so that it will not come in
touch with placed components. If necessary, the nozzle has to be manually removed.
If a long/wide component is placed by the active segment, no check will be performed whether
a component is wiped off from the segment that has been removed from the configuration.
PCB barcode detection with Molex Traceability Pad
Barcode-controlled production is not supported.
Traceability is not possible until the barcode has been successfully read. Therefore, the
Traceability Pad should be placed / read in placement area 1 of the first placement machine in
the line. Only in this case, it is warranted that the Traceability information can be correctly
saved for all stations in the line.
Barcodes can only be reliably measured by SIPLACE Vision if the component height (without
board warpage) at the position of the Traceability-Pad is < 1,5mm.
When the placement position is taught, the barcode / fiducial position will not be moved
correspondingly.
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
60
10 Corrected Errors
10.1 706.1 SP2 Station Software
Station software version 706.1 SP2 contains all the error corrections of the previous versions
701.xx 706.1 SP1. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-74832811
Height control errors frequently occured when the trays were returned into the
tower.
D1-78661201 The MTC did not consider the acceleration reduction.
D1-79243301 Too long time for downloading a new recipe and setup to the station.
D1-80541901
D16837-1398
This error occurred sporadically when the machine was started:
Head configuration not supported for this machine. Can't
initialize machine hardware
.
D1-81048513
D1-85016987
The "Name" column displaying the placement reference position was missing
in the 706 station software.
D1-82180701
The nozzle was out of center in front of the component camera after a feeder
change and the track was deactivated.
D1-83201901 The machine stopped the production after not having recognized an ink spot.
D1-83344201 The placement position could not be taught.
D1-84180931 Misleading error message for measurement errors during calibration.
D1-84221817 The MTC reference run failed on an X3 S placement machine.
D1-84355807 The cutting unit did not work if only X-feeders 56-88mm were set up.
D1-84734801
D1-86050901
D1-86095301
D16775-4658
After sending a new product the feeder position recognition sporadically failed.
D1-84955201
eSW: the board was not transported to the output conveyor after the conveyor
width had been adjusted
D1-85017141 Sporadically, there were some question marks in the PCB conveyor view.
D1-85076201
The "Feed forward" function did not work when the pickup position was
checked.
D1-85401001
The machine displayed error message 30464 Current of servo
amplifier or motor exceeds threshold
.
D1-85401043
eSW: error message 40006 Board cannot reach target position
although the board was over the sensor.
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
61
Error no. Error description
D1-85847311
Holding vacuum values were not displayed correctly when the filter plates
were tested.
D1-85871081 eSW: BIOS V01.01 for the LDU was missing in the eSW pool.
D1-85873213 Empty pin garages were not displayed correctly.
D1-86009357
D1-86920701
The calibration was aborted with a conveyor error after a gantry exchange.
D1-86174924
D1-87501501
The machine stopped during production and could not be started again.
D1-86190301
D1-85897301
D16575-6907
After the first installation of 706.1.SP1 C&P20A heads were no longer
recognized.
D1-86194907 The BUG report was visible in the background.
D1-86349451
For multiple set-up components the "Feeder is missing" display failed for not
positioned components.
D1-86351372
D1-86357901
The pick-up position got inaccurate after a while.
D1-86377401
D1-86551501
The extended interface was not offered within the conveyor configuration.
D1-86379401
In the placement list the options could only be changed by SIPLACE service.
Customer service should also be allowed to do this.
D1-86394915 Feeding on demand for 1x8 and 2x8 X feeders did not work properly.
D1-86404401
eSW: the mounted board was not transported due to an error in the control
voltage.
D1-86432701
The support pin in the pin magazine was not recognized on an X4 S
placement machine.
D1-86616801 The nozzle ID of nozzle type 2020 was not recognized.
D1-86654502
eSW: Machine was locked after a moving error and manual removement of
the PCB from the output conveyor.
D1-86736801
D1-82577101
It was possible for the operator to log out directly from the GUI under
Windows 7.
D1-86762641 The machine got into an infinite loop during the firmware upgrade.
D1-86788354 eSW: hang-up due to activation of watchdog conveyor control board.
D1-86894185
eSW: the board was not transported into the next machine although the
conveyor was empty.
D1-86897701
D16901-8007
D17049-6511
An X4 placement machine (with Twin + CPP) reported an error: 30470 Either
collision of two gantries or axis hit bumper at end of driving range.
D1-86926901 eSW: removing a board did not work correctly.
D1-86988501
eSW: the FCU sub-system was not responding and the table was no longer
reachable.