00197043-04_VD_706_1_SP2_705_05_SP2_DE_EN.pdf - 第67页
Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 67 Error n o. Error de scriptio n D1 - 73931701 The pin p icker c ould not be c alibrated, b ecause the s upport pin was too cl…

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
66
10.3 706.1 Station Software
Station software version 706.1 contains all the error corrections of the previous versions
701.xx – 706.0. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-62595101 Troubleshooting difficult because no component name was displayed für the
placement heads and segments in the error message for the z-axis.
D1-63468662 The tray was feeded in spite of the refill position.
D1-63494246 The pick-up angle at the MTC2 was not transferred to SIPLACE Pro even though
uploading was activated.
D1-64522301 An SX2 placement machine stopped after 2.5 hours nighttime run with an error
message that the z-axis could not be moved to a safe position.
D1-66198001 An incorrect pick-up position was approached in the tray.
D1-66633301 The station software hung up after the teaching of a component shape failed.
D1-66918811 Too big difference between two component sensor values on C&P20 placement
heads on an X4 placement machine.
D1-67030701 It was not possible to move to the refill position during production.
D1-68408901 A table at an SX-series placement machine could not be docked as the cover was
opened. The "Unspecified hardware error" message was misleading.
D1-69233218 Traveling parameters could not be set for the axis.
D1-69239712
D1620-8901
The CPP placement head wiped off tall components on an SX-series placement
machine.
D1-70141578 A missing tray in the WPC was not marked in red on the GUI of the station
software.
D1-70180045 After the width had been adjusted, the current width was not displayed.
D1-70928401 After the 3D coplanarity measurement, a component was not put back correctly into
the tray.
D1-71252701 At a track error on an X3 placement machine the wrong lamp indicator was
illuminated.
D1-72413212 An error message about a potential gantry collision was displayed after the cover
had been opened and closed on an X4 placement machine.
D1-73126941 Smart Pin Support did not function in safe mode.
D1-73291201 Smart support pins could not be automatically positioned.
D1-73637347 During teaching, an incomprehensible error message was displayed:
Machine position no longer exists
.
D1-73678601 When the pick-up position was taught, it was shown displaced by approximately
1mm, depending on whether the Show entire component option was enabled or
disabled.
D1-73895501 The station software hung up after the position recognition on an X4i placement
machine.
D1-73895600
D1-73126901
D1-74130301
D1-76087441
The 32434 and 32433 error messages were displayed in connection with Smart
Pin Support. No components were present on the underside of the board.

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
67
Error no. Error description
D1-73931701 The pin picker could not be calibrated, because the support pin was too closely
positioned to the conveyor.
D1-73963801 An SX-series placement machine could not be initialized and had to be rebooted.
D1-74085991 After a board had been assembled in Recovery mode and the same program was
downloaded from SIPLACE Pro to the placement machine, this setup was not
completed.
D1-74361401 Air pressure adjustment only functioned if the air pressure deactivation was
enabled.
D1-74610501 The traveling range could not be measured.
D1-74674301 An SX-series placement machine with a loaded board stopped without any error
message. Thereafter, the keyboard did not function correctly.
D1-74774701 For user-defined settings of the fixed rail, values between 0.00 and 0.00 were
available only.
D1-75917101 The x-axis position was outside the traveling range.
D1-76104851
D1-76657847
Head mapping error on an SX-series placement machine.
D1-76146401 The number of cycles was too high for the Smart Pin Support endurance run.
D1-76359294
D1-76320101
D1-76359201
D1-76359252
D1-76712470
If the 2x8mm X-feeder was positioned on another track, this was not identified as
an alternative track by the station.
D1-77925001 Error message during production: Bottom light barrier triggered even
though positioning mode is absolute
.
D16273-9267 When many error information messages were displayed on the GUI simultaneously,
the screen slowed down a lot.
Table 10-3: Corrected errors 706.1 station software
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
68
11 Important Terms and Abbreviations
ACT Accuracy Check Tool
C&P Collect & Place
CPP Collect & Place & Pick & Place
DC Dual Conveyor
DX1/DX2 Machine type with 1 or 2 gantries
DX4 Machine type with 4 gantries
EDIF Electronic Design Interchange Format
FCCS Field Camera Calibration System
GCU Gantry Control Unit (new electronic concept for X4i)
GUI Graphical User Interface
HCU Head Control Unit (new electronic concept for X4i)
HFH High Force Head
HW Hardware
MTC Matrix Tray Changer
OIS Operator Information System
PA Processing area
PCB Printed circuit board
QC Quad Lane Conveyor
SC Single Conveyor
SC SIPLACE Setup Center (external setup station)
SSI SIPLACE Station Interface
SW Software
SX1/SX2 Machine type with 1 or 2 gantries
SX3 Machine type with 3 gantries
SX4 Machine type with 4 gantries
VC Vision computer
VCU Vision Control Unit
VHF P&P Very High Force Pick&Place
WPC Waffle Pack Changer
X2 Machine type with 2 gantries