00197043-04_VD_706_1_SP2_705_05_SP2_DE_EN.pdf - 第68页
Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 68 11 Impor tant T erms and A bbr ev iations ACT Accurac y Check Tool C&P Collect & Place CPP Collect & Place &…

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
67
Error no. Error description
D1-73931701 The pin picker could not be calibrated, because the support pin was too closely
positioned to the conveyor.
D1-73963801 An SX-series placement machine could not be initialized and had to be rebooted.
D1-74085991 After a board had been assembled in Recovery mode and the same program was
downloaded from SIPLACE Pro to the placement machine, this setup was not
completed.
D1-74361401 Air pressure adjustment only functioned if the air pressure deactivation was
enabled.
D1-74610501 The traveling range could not be measured.
D1-74674301 An SX-series placement machine with a loaded board stopped without any error
message. Thereafter, the keyboard did not function correctly.
D1-74774701 For user-defined settings of the fixed rail, values between 0.00 and 0.00 were
available only.
D1-75917101 The x-axis position was outside the traveling range.
D1-76104851
D1-76657847
Head mapping error on an SX-series placement machine.
D1-76146401 The number of cycles was too high for the Smart Pin Support endurance run.
D1-76359294
D1-76320101
D1-76359201
D1-76359252
D1-76712470
If the 2x8mm X-feeder was positioned on another track, this was not identified as
an alternative track by the station.
D1-77925001 Error message during production: Bottom light barrier triggered even
though positioning mode is absolute
.
D16273-9267 When many error information messages were displayed on the GUI simultaneously,
the screen slowed down a lot.
Table 10-3: Corrected errors 706.1 station software
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
68
11 Important Terms and Abbreviations
ACT Accuracy Check Tool
C&P Collect & Place
CPP Collect & Place & Pick & Place
DC Dual Conveyor
DX1/DX2 Machine type with 1 or 2 gantries
DX4 Machine type with 4 gantries
EDIF Electronic Design Interchange Format
FCCS Field Camera Calibration System
GCU Gantry Control Unit (new electronic concept for X4i)
GUI Graphical User Interface
HCU Head Control Unit (new electronic concept for X4i)
HFH High Force Head
HW Hardware
MTC Matrix Tray Changer
OIS Operator Information System
PA Processing area
PCB Printed circuit board
QC Quad Lane Conveyor
SC Single Conveyor
SC SIPLACE Setup Center (external setup station)
SSI SIPLACE Station Interface
SW Software
SX1/SX2 Machine type with 1 or 2 gantries
SX3 Machine type with 3 gantries
SX4 Machine type with 4 gantries
VC Vision computer
VCU Vision Control Unit
VHF P&P Very High Force Pick&Place
WPC Waffle Pack Changer
X2 Machine type with 2 gantries
X3/X3 S Machine type with 3 gantries
X4/X4 S Machine type with 4 gantries
X4i/X4i S Machine type with 4 gantries

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
69
12 Licenses
When using linear algebra, the SIPLACE station software utilizes the Eigen template library.
Eigen is free software and is licensed under the GNU LGPL3+ (http://eigen.tuxfamily.org
).
The license terms for GNU LGPL3+ can be found on the station software product CD in the
(License) directory.