00197043-04_VD_706_1_SP2_705_05_SP2_DE_EN.pdf - 第65页
Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 65 Error n o. Error de scriptio n D1 - 82588449 Flash beha vior of the green lam p indicator changed d uring pr oduct chang e. …

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
64
10.2 706.1 SP1 Station Software
Station software version 706.1 SP1 contains all the error corrections of the previous versions
701.xx – 706.1. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-68758343
D1-71144501
D1-81901140
LBO stopper was not operable in the I/O menu.
D1-75873801 Tape cutter did not cut, if only DATA I/O Roadrunner was available at the
location.
D1-77216101
D1-77750755
After that two conveyor lanes ran, only one conveyor lane ran during
production. The board in the input section was not moved into the machine.
D1-77938809
D1-75629551
D1-78186801
D16683-3718
The boards were not transported due to an error in the conveyor controller.
D1-78346955 Conveyor problem: the board moved in up to the light barrier, then it was
recognized as "clambing".
D1-79950501 The software sporadically hung up after a board fiducial error.
D1-81283201 The PCB barcode was not passed on from one module to another.
D1-81760302 Error during readout of the statistics data.
D1-81826901 eSW: Wrong sequence within the axis led to non-operating machine.
D1-81835901 No update at the station by Line Control after fiducial settings were changed
on a board.
D1-81888301
D1-81901901
D1-82777543
Error message: Twin segment down, if emergency stop loop was interrupted
and the stop button was not pressed before.
D1-81975778 The machine displayed a message that nozzle 532 was not referenced.
D1-82132701 eSW: CP20a heads were sporadically recognized as new heads or the
component sensor values were still not valid after calibration.
D1-82153375
D1-82151202
All support pins were put back into the magazines and set on the table again
after "Start" was pressed after "Stop".
D1-82160701
D1-82169801
Machine stopped because of too many repeated errors at segment 5.
D1-82569701 Error in the lamp indicator controller of the white lamp indicator at "Warning".
D1-82588401 Faulty flashing of green lamp indicator: short flashing instead of normal
flashing.

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
65
Error no. Error description
D1-82588449 Flash behavior of the green lamp indicator changed during product change.
D1-82604011 Unhandled Exception within SirioConsole.exe.
D1-82620574 Unknown placement state.
D1-82620901 Teaching the zero point of the machine was inverse to the Vision display.
D1-82633901 The "Loading board" function was aborted with an error message for the
embedded software.
D1-82747057 After timeout for the DP axis, the station had to be rebooted.
D1-82759001
D1-82597601
Coplan MFU did not function on an SX1/SX2 placement machine.
D1-82793701 Conveyor lane 2 was locked although a job was defined.
D1-82802953 Sporadically, the GUI did not start after a reboot.
D16901-4109 eSW: 12/16mm X smart feeders sporadically reported foil broken errors
although there was no foil torn.
Table 10-2: Corrected errors 706.1 SP1 station software

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
66
10.3 706.1 Station Software
Station software version 706.1 contains all the error corrections of the previous versions
701.xx – 706.0. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-62595101 Troubleshooting difficult because no component name was displayed für the
placement heads and segments in the error message for the z-axis.
D1-63468662 The tray was feeded in spite of the refill position.
D1-63494246 The pick-up angle at the MTC2 was not transferred to SIPLACE Pro even though
uploading was activated.
D1-64522301 An SX2 placement machine stopped after 2.5 hours nighttime run with an error
message that the z-axis could not be moved to a safe position.
D1-66198001 An incorrect pick-up position was approached in the tray.
D1-66633301 The station software hung up after the teaching of a component shape failed.
D1-66918811 Too big difference between two component sensor values on C&P20 placement
heads on an X4 placement machine.
D1-67030701 It was not possible to move to the refill position during production.
D1-68408901 A table at an SX-series placement machine could not be docked as the cover was
opened. The "Unspecified hardware error" message was misleading.
D1-69233218 Traveling parameters could not be set for the axis.
D1-69239712
D1620-8901
The CPP placement head wiped off tall components on an SX-series placement
machine.
D1-70141578 A missing tray in the WPC was not marked in red on the GUI of the station
software.
D1-70180045 After the width had been adjusted, the current width was not displayed.
D1-70928401 After the 3D coplanarity measurement, a component was not put back correctly into
the tray.
D1-71252701 At a track error on an X3 placement machine the wrong lamp indicator was
illuminated.
D1-72413212 An error message about a potential gantry collision was displayed after the cover
had been opened and closed on an X4 placement machine.
D1-73126941 Smart Pin Support did not function in safe mode.
D1-73291201 Smart support pins could not be automatically positioned.
D1-73637347 During teaching, an incomprehensible error message was displayed:
Machine position no longer exists
.
D1-73678601 When the pick-up position was taught, it was shown displaced by approximately
1mm, depending on whether the Show entire component option was enabled or
disabled.
D1-73895501 The station software hung up after the position recognition on an X4i placement
machine.
D1-73895600
D1-73126901
D1-74130301
D1-76087441
The 32434 and 32433 error messages were displayed in connection with Smart
Pin Support. No components were present on the underside of the board.