00197043-04_VD_706_1_SP2_705_05_SP2_DE_EN.pdf - 第63页
Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 63 Error n o. Error de scriptio n D16878 - 99 09 D17056 - 19 09 D17183 - 20 1 S ometim es the conve yor of X 4i S and X4 S plac…

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
62
Error no. Error description
D1-87381901
Different values for the gantries during the zero compensation of the pressure
control on an X4 S placement machine.
D1-87407611 Incorrect nozzle angle for the pickup.
D1-87625301
After software installation the machine started with an unexpected error and
Windows had to be restarted.
D1-87625341 The machine detected new heads after calibration.
D1-87699101
D1-88063501
Dirty nozzles were rejected on an X4 S placement machine although the
corresponding settings were deactivated.
D1-87736101
An X3 S placement machine could not be put into operation because the
machine searched for a non-available nozzle changer.
D1-87848301 Pin picker magazines without a board were not recognized by the software.
D1-87988601
D1-84260938
D1-87501541
The machine stopped during placement and the Start button had to be
pressed to continue.
D1-88005501 Production in production area 2 stopped suddenly.
D1-88384401
X S-series placment machines threw away bigger components at the wrong
position.
D16223-6711
D1-58494401
D1-60422901
D1-67917601
D16849-4907
D16747-5948
Different cycle times in SIPLACE Pro and on the machine.
D16600-2278 eSW: Auto recovery failed in lane1 after the machine restarted.
D16600-2333 The machine stopped during normal production.
D16633-4310 eSW: WPC 6 with non-stop module stopped during production run.
D16714-1610
After an MTC error the operator was prompted to terminate Windows and
restart the machine.
D16771-9107 eSW: sporadically, feeders were unlocked.
D16803-9613
D1-80501601
D17056-1807
Sporadic software crash when components were taught.
D16837-1398
Machine hardware could not be initialized (placement head configuration not
supported for this machine type after exchange of a segment).
D16865-3207 eSW: Enhancement of the robustness when the dp axis was positioned.
D16878-9009 The support pin was incorrectly positioned by the pin picker.
D16878-9809
D17186-410
eSW: X4 S: lane1 PA1 PCB was placed twice.

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
63
Error no. Error description
D16878-9909
D17056-1909
D17183-201
Sometimes the conveyor of X4i S and X4 S placement machines did not
transfer the board to the next station.
D16879-2111 eSW: Software hung up after an error when moving into input section.
D16901-7079 Machine hardware could not be initialized.
D17183-32 Calibrated table position was lost after reboot.
Table 10-1: Corrected errors 706.1 SP2 station software

Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
64
10.2 706.1 SP1 Station Software
Station software version 706.1 SP1 contains all the error corrections of the previous versions
701.xx – 706.1. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-68758343
D1-71144501
D1-81901140
LBO stopper was not operable in the I/O menu.
D1-75873801 Tape cutter did not cut, if only DATA I/O Roadrunner was available at the
location.
D1-77216101
D1-77750755
After that two conveyor lanes ran, only one conveyor lane ran during
production. The board in the input section was not moved into the machine.
D1-77938809
D1-75629551
D1-78186801
D16683-3718
The boards were not transported due to an error in the conveyor controller.
D1-78346955 Conveyor problem: the board moved in up to the light barrier, then it was
recognized as "clambing".
D1-79950501 The software sporadically hung up after a board fiducial error.
D1-81283201 The PCB barcode was not passed on from one module to another.
D1-81760302 Error during readout of the statistics data.
D1-81826901 eSW: Wrong sequence within the axis led to non-operating machine.
D1-81835901 No update at the station by Line Control after fiducial settings were changed
on a board.
D1-81888301
D1-81901901
D1-82777543
Error message: Twin segment down, if emergency stop loop was interrupted
and the stop button was not pressed before.
D1-81975778 The machine displayed a message that nozzle 532 was not referenced.
D1-82132701 eSW: CP20a heads were sporadically recognized as new heads or the
component sensor values were still not valid after calibration.
D1-82153375
D1-82151202
All support pins were put back into the magazines and set on the table again
after "Start" was pressed after "Stop".
D1-82160701
D1-82169801
Machine stopped because of too many repeated errors at segment 5.
D1-82569701 Error in the lamp indicator controller of the white lamp indicator at "Warning".
D1-82588401 Faulty flashing of green lamp indicator: short flashing instead of normal
flashing.