00197043-04_VD_706_1_SP2_705_05_SP2_DE_EN.pdf - 第63页

Station S oftware 70 6. 1 SP 2 /705.05 SP 2 / Vers ion De scription Ausgabe 07/2013 E dition 63 Error n o. Error de scriptio n D16878 - 99 09 D17056 - 19 09 D17183 - 20 1 S ometim es the conve yor of X 4i S and X4 S plac…

100%1 / 144
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
62
Error no. Error description
D1-87381901
Different values for the gantries during the zero compensation of the pressure
control on an X4 S placement machine.
D1-87407611 Incorrect nozzle angle for the pickup.
D1-87625301
After software installation the machine started with an unexpected error and
Windows had to be restarted.
D1-87625341 The machine detected new heads after calibration.
D1-87699101
D1-88063501
Dirty nozzles were rejected on an X4 S placement machine although the
corresponding settings were deactivated.
D1-87736101
An X3 S placement machine could not be put into operation because the
machine searched for a non-available nozzle changer.
D1-87848301 Pin picker magazines without a board were not recognized by the software.
D1-87988601
D1-84260938
D1-87501541
The machine stopped during placement and the Start button had to be
pressed to continue.
D1-88005501 Production in production area 2 stopped suddenly.
D1-88384401
X S-series placment machines threw away bigger components at the wrong
position.
D16223-6711
D1-58494401
D1-60422901
D1-67917601
D16849-4907
D16747-5948
Different cycle times in SIPLACE Pro and on the machine.
D16600-2278 eSW: Auto recovery failed in lane1 after the machine restarted.
D16600-2333 The machine stopped during normal production.
D16633-4310 eSW: WPC 6 with non-stop module stopped during production run.
D16714-1610
After an MTC error the operator was prompted to terminate Windows and
restart the machine.
D16771-9107 eSW: sporadically, feeders were unlocked.
D16803-9613
D1-80501601
D17056-1807
Sporadic software crash when components were taught.
D16837-1398
Machine hardware could not be initialized (placement head configuration not
supported for this machine type after exchange of a segment).
D16865-3207 eSW: Enhancement of the robustness when the dp axis was positioned.
D16878-9009 The support pin was incorrectly positioned by the pin picker.
D16878-9809
D17186-410
eSW: X4 S: lane1 PA1 PCB was placed twice.
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
63
Error no. Error description
D16878-9909
D17056-1909
D17183-201
Sometimes the conveyor of X4i S and X4 S placement machines did not
transfer the board to the next station.
D16879-2111 eSW: Software hung up after an error when moving into input section.
D16901-7079 Machine hardware could not be initialized.
D17183-32 Calibrated table position was lost after reboot.
Table 10-1: Corrected errors 706.1 SP2 station software
Station Software 706.1 SP2/705.05 SP2 / Version Description Ausgabe 07/2013 Edition
64
10.2 706.1 SP1 Station Software
Station software version 706.1 SP1 contains all the error corrections of the previous versions
701.xx 706.1. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-68758343
D1-71144501
D1-81901140
LBO stopper was not operable in the I/O menu.
D1-75873801 Tape cutter did not cut, if only DATA I/O Roadrunner was available at the
location.
D1-77216101
D1-77750755
After that two conveyor lanes ran, only one conveyor lane ran during
production. The board in the input section was not moved into the machine.
D1-77938809
D1-75629551
D1-78186801
D16683-3718
The boards were not transported due to an error in the conveyor controller.
D1-78346955 Conveyor problem: the board moved in up to the light barrier, then it was
recognized as "clambing".
D1-79950501 The software sporadically hung up after a board fiducial error.
D1-81283201 The PCB barcode was not passed on from one module to another.
D1-81760302 Error during readout of the statistics data.
D1-81826901 eSW: Wrong sequence within the axis led to non-operating machine.
D1-81835901 No update at the station by Line Control after fiducial settings were changed
on a board.
D1-81888301
D1-81901901
D1-82777543
Error message: Twin segment down, if emergency stop loop was interrupted
and the stop button was not pressed before.
D1-81975778 The machine displayed a message that nozzle 532 was not referenced.
D1-82132701 eSW: CP20a heads were sporadically recognized as new heads or the
component sensor values were still not valid after calibration.
D1-82153375
D1-82151202
All support pins were put back into the magazines and set on the table again
after "Start" was pressed after "Stop".
D1-82160701
D1-82169801
Machine stopped because of too many repeated errors at segment 5.
D1-82569701 Error in the lamp indicator controller of the white lamp indicator at "Warning".
D1-82588401 Faulty flashing of green lamp indicator: short flashing instead of normal
flashing.