00193411-02.pdf - 第104页

4 Setting up t he placement system User Manual SIPLACE HS-60 4.3 Converting the com ponent trolley for other PCB transport heights Software version SR. 503.xx 07/2003 US Edition 104 4.3 Converting the componen t trolley …

100%1 / 198
User Manual SIPLACE HS-60 4 Setting up the placement system
Software version SR.503.xx 07/2003 US Edition 4.2 Setting up the placement system
103
3 x 16 A for 3 x 380 VAC 4
3 x 16 A for 3 x 400 VAC 4
3 x 16 A for 3 x 415 VAC 4
4
4
4.2 Setting up the placement system
Æ Raise the placement system using the fork-lift truck and adjust the feet until there is a gap of
830 mm (950 mm SMEMA height) between the top edge of the PCB conveyors and the bot-
tom edge of the feet.
Æ Leave a gap of 1 to 3 mm between the PCB conveyors of the placement system.
Æ Align all the placement systems exactly in line with one another. Use a cord pulled tight to en-
sure this.
Æ Adjust each placement system using a spirit level with an accuracy of 0.02 mm/m.
Æ Lock the feet in position.
Æ Check the placement system again using the spirit level and correct the settings, if necessary.
CAUTION
Make sure that you remove all the shipping braces from the placement system. 4
Æ Fit any components that were dismantled for dispatch.
Æ Connect all the electrical and pneumatic lines.
RISK OF DEATH
The electrical connection work MUST be carried out only by appropriately trained and cer-
tified personnel. 4
4 Setting up the placement system User Manual SIPLACE HS-60
4.3 Converting the component trolley for other PCB transport heights Software version SR.503.xx 07/2003 US Edition
104
4.3 Converting the component trolley for other PCB
transport heights
4.3.1 Tools
Allen key, set up to 8 mm
4.3.2 Safety instructions
WARNING DANGER OF CRUSHING 4
Remove all the feeders from the table bed before you change the height of the table on the com-
ponent trolley. Take care during the conversion work because the table bed is very heavy. 4
4
Fig. 4.3 - 1 Converting the component trolley for another PCB transport height
(1) Clamping screws, 4 on each side
(2) Holes in the cross-beam for setting the table height to 830, 900, 930 and 950 mm
User Manual SIPLACE HS-60 4 Setting up the placement system
Software version SR.503.xx 07/2003 US Edition 4.3 Converting the component trolley for other PCB transport heights
105
Æ Insert the two Allen keys (8 mm) into the holes for the current PCB transport height (see Fig.
4.3 - 1
).
Æ Loosen the four clamping screws on each side of the component trolley (see point 1 in Fig. 4.3
- 1).
Æ Ask two people to help you raise and lower the table bed. They should hold the table bed while
you remove the two Allen keys.
Æ Raise or lower the table bed to the required PCB transport height.
Æ Push the two Allen keys (8 mm) into the holes for the new transport height.
Æ Turn the Allen keys so that the cross-beam (item 2 in Fig. 4.3 - 1) is seated on the edge of the
key. The Allen keys can then be removed easily after fixing the cross-beam.
Æ Fix the cross-beam on both sides using the four clamping screws (item 1 in Fig. 4.3 - 1).
Æ Now turn the Allen keys slightly and pull them out.