2 Operational safety User Manual SIPLACE HS-60
2.8 Energy state of the machine after switching off at the main power switch Software version SR.503.xx 07/2003 US Edition
62
2
Fig. 2.8 - 1 Position of the servo unit, main power switch, service socket,
and compressed air unit in the placement system
2
(1) Main power switch
(2) Service socket behind the safety door
(3) Compressed air unit
(4) Servo unit
(5) Measuring unit in the servo unit
User Manual SIPLACE HS-60 2 Operational safety
Software version SR.503.xx 07/2003 US Edition 2.8 Energy state of the machine after switching off at the main power switch
63
2
Fig. 2.8 - 2 Position of control unit and main power switch
2
(1) Main power switch
(2) Control unit
(3) Power supply unit ± 12 VDC
(4) Power supply unit ± 15 VDC
(5) Power supply unit + 5 VDC/+ 24 VDC
(6) Power supply unit + 5 VDC/+ 52 VDC
2 Operational safety User Manual SIPLACE HS-60
2.8 Energy state of the machine after switching off at the main power switch Software version SR.503.xx 07/2003 US Edition
64
2.8.1 Placement system switched off at the main power switch, but still connected ...
The following table specifies the voltages of modules when the automatic placement system is
switched off at the main switch, but still connected to the mains supply.
WARNING 2
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
Cable connection terminals 1, 3, and 5 of the S1 main power switch
Mains filter Z1
BU1 service socket
F1 automatic circuit breaker for the service socket
The color of all individual wires, which still carry potentially lethal voltages even if the main
power switch is switched off, is brown.
2
Module Voltage
Main power filter Z1
Terminals L1, L2, L3
3 x 204 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
BU1 service socket
115 VAC
130 VAC
220 VAC
230 VAC
240 VAC
F1 automatic circuit breaker
115 VAC
130 VAC
220 VAC
230 VAC
240 VAC