User Manual SIPLAC E HS-60 7 Station extensions Software vers ion SR.503.xx 07/2003 US Edit ion 7.1 Nozzle changer f or the 12-segm ent Collect&Place head 153 (8) Parall el pins for opening and cl osing the locki ng …

7 Station extensions User Manual SIPLACE HS-60
7.1 Nozzle changer for the 12-segment Collect&Place head Software version SR.503.xx 07/2003 US Edition
152
7
Fig. 7.1 - 2 Magazine and nozzle garages
(1) Positioning fiducial
(2) Locking plate
(3) Nozzle holder
(4) Hole for the parallel pin for centering the magazines
(5) Hole for the parallel pin of the slide mechanism
(6) Slot for the parallel pin for centering the magazines
(7) Parallel pin for centering the magazines
12 3
4
10 11
12
9
5
6
7
8

User Manual SIPLACE HS-60 7 Station extensions
Software version SR.503.xx 07/2003 US Edition 7.1 Nozzle changer for the 12-segment Collect&Place head
153
(8) Parallel pins for opening and closing the locking plate
(9) Magazines
7.1.4 Notes on operation
Æ
When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
PLEASE NOTE 7
Only ONE nozzle type must be used in each magazine.
Fill the magazines off the machine and always replace complete magazines. 7
Æ Open the locking plate and place the nozzles in the nozzle holders.
Æ Close the locking plate so that the nozzles cannot drop out of the magazines.
CAUTION 7
Before you fill magazine, make sure that all the nozzles on the Collect&Place head have
been returned to their magazines. 7
Æ Programming the nozzle changer is described in the User manuals for the UNIX line computer
and the SIPLACE Pro computer.
PLEASE NOTE 7
Æ Do not allow components to drop onto the magazines. If they do, they could jam the locking
plate.
Æ Do not allow components to drop onto free feeder locations. They will stick to the magnetic bar.
Production may have to be interrupted if the feeders are not placed on the component table
correctly. You should therefore regularly clean the magazines and free locations.

7 Station extensions User Manual SIPLACE HS-60
7.1 Nozzle changer for the 12-segment Collect&Place head Software version SR.503.xx 07/2003 US Edition
154
7.1.5 Changing the magazine
Æ To remove the magazine, push the spring hook (item 1 in Fig. 7.1 - 3) away from the maga-
zine. Lift the magazine out of the carrier.
7
Fig. 7.1 - 3 Changing the magazine
(1) Spring hook
(2) Retaining clamp
(3) Centering hole
(4) Slot
(A) Push the spring hook away from the magazine