X-Series-Maintenance-Manual(1).pdf - 第116页

Major Maintenance Maintenance Tasks for C&P6 /12 Head Final Work 116 Maintenance Manual SIPLACE X Series Final W ork 5.7.4 Final Work Fitting the front section of the head ► Insert the two O-rings int o the back par …

100%1 / 118
Major Maintenance
Performing Maintenance Tasks Maintenance Tasks for C&P6/12 Head
Maintenance Manual SIPLACE X Series 115
Component sensor (only DLM3)
5.7.3.9 Component sensor (only DLM3)
CAUTION
Installation instructions
Carefully screw the vacuum generator block with the vacuum nozzles tight.
Before the Venturi nozzles are refitted with the O-rings, make sure that the ethanol has
evaporated completely. If this is not the case, the O-rings could be dissolved over time by
the ethanol.
CAUTION
Take care not to damage the component sensor prisms.
Make sure that you do not use the cottonwool buds soaked in oil from cleaning the sleeves.
Always use a new cottonwool bud!
Clean the prisms of the component sensor with a
cottonwool bud soaked in ethanol.
Major Maintenance
Maintenance Tasks for C&P6/12 Head Final Work
116 Maintenance Manual SIPLACE X Series
Final Work
5.7.4 Final Work
Fitting the front section of the head
Insert the two O-rings into the back part of head.
Carefully insert the distributor into its seat.
Turn the placement star half a step (C&P6: 30°, C&P12: 15°), fit the front part of the head and screw
tight.
Attach the ribbon cables to the appropriate connectors.
Insert cleaned or new sleeves into the segments.
Insert cleaned or new valve plungers into the valve casings.
Fitting the placement head
Fit the placement head back onto the gantry. Read the service manual for the respective machine
first.
Switch the placement machine on at the main switch.
Let the placement head take up the nozzles again.
Test placement:
The distance between the component camera and the PCB camera can be changed by separating
the front and back parts of the head.
Carry out a test placement run to test whether the placement accuracy is still guaranteed.
If the placement accuracy is not guaranteed, calibrate the segment offset 2.
CAUTION
The O-rings must not be seated on the distributor, otherwise they may be damaged.