Minor Maintenance
Preparatory Steps Maintenance Tasks for Nozzles
Maintenance Manual SIPLACE X Series 49
Preparatory Steps
4.7.3 Preparatory Steps
► Set the nozzles down in the nozzle changer.
Performing Maintenance Tasks
4.7.4 Performing Maintenance Tasks
Cleaning /Replacing the Ce ramic Nozzles
4.7.4.1 Cleaning/Replacing the Ceramic Nozzles
CAUTION
Do not clean the nozzles in bulk!
Cleaning the nozzles in bulk can damage the ceramic tips (through impact with one another or
with the cleaning vessel), and/or the plastic shaft (through contact with the cleaning fluid).
► Always use the the cleaning box described here!
NOTICE
These maintenance tasks are described using the example of a nozzle magazine for DLM
heads.
The procedure is the same for other nozzle magazines.
► Remove a full nozzle magazine from the nozzle
changer. When handling a nozzle magazine which is
not full, pay attention to the orientation in the nozzle
changer. At the end of the cleaning procedure, make
sure that the nozzle magazine is reinserted into the
nozzle changer with the same orientation.
CAUTION! If you are using both plastic and
ceramic nozzles in the same magazine, remove the
plastic nozzles. Plastic nozzles can not be cleaned with
the ultrasonic bath.
► Press the cleaning box onto the nozzle magazine.

Minor Maintenance
Maintenance Tasks for Nozzles Performing Maintenance Tasks
50 Maintenance Manual SIPLACE X Series
► Open the slide on the nozzle magazine.
► Pull off the cleaning box, together with the nozzles.
CAUTION! Make sure that the nozzle tips do not
come into contact with the cleaning vessel or other metal
parts.
During cleaning, make sure that only the ceramic tips
come into direct contact with the cleaning fluid.
NOTICE! Use the cartridge rack 10xx
[03071700
-
xx] for C&P20 and CPP nozzles.
► Fill the ultrasonic bath with distilled water. Make sure
you have the correct level. (1). Observe the following
instructions:
CAUTION
Filling level for ultrasonic bath
► Only the ceramic tips may come into continuous contact with the cleaning fluid. These
should reach into the fluid by approx. 2 mm.
► The water level should not exceed or undershoot the prescribed height by more than 2 mm
as this could impair the cleaning effect.

Minor Maintenance
Performing Maintenance Tasks Maintenance Tasks for Nozzles
Maintenance Manual SIPLACE X Series 51
► Place the cleaning box with the nozzle tips facing
downwards into the ultrasonic bath.
CAUTION! The nozzle magazines may not be
placed into the water.
The recommended cleaning time for nozzles with normal
levels of dirt is 15 min.
The time needed depends on the degree of dirt.
► At the end of the cleaning time, take the cleaning box
out of the ultrasonic bath.
► Turn the cleaning box so that the nozzle tips face
upwards.
► Place the guidance for the plastic brush into the
cleaning box.