Minor Maintenance
Maintenance Tasks for Base Machine Performing Maintenance Tasks
32 Maintenance Manual SIPLACE X Series
Performing Maintenance Tasks
4.2.3 Performing Maintenance Tasks
Checking and Cleaning/Replacing the Compressed Air Filter (if required)
4.2.3.1 Checking and Cleaning/Replacing the Compressed Air Filter (if required)
CAUTION! Before checking or replacing the
compressed air filters, you need to shut off the supply of
air!
Use the machine key to open the door to the
compressed air supply, detach the cable and remove
the door.
Turn the main compressed air valve (1) clockwise. All
manometers must be set to zero.
Loosen the screw (2) , and pull out the compressed
air supply.
Place the collecting vessel under the compressed air
supply.
Open the screw (1) beneath the cover cap (2) to
release the pressure.
Pull the locking lever (1) on the cover downwards.
Press the cover (2) upwards and unscrew by turning
to the left (3).
Unscrew the compressed air filter (4) and check for
dirt.
Replace the filter if it is dirty.
Filter element 5 μm [03050213-xx]
HSxx / D1 / D2 / D4 / SX series / X series from
March 2008 pneumatic valve [03062274-xx]
(for [03060279-xx] pneumatic unit)
Replacement filter for 5 μm compressed air filter
for pneumatic valve [03038979-xx]
X series up to SN B089 [03004680-xx]
(for [03004151-xx] pneumatic unit)
Filter element for 5 μm filter (new) for pneumatic
valve [03039182-xx]
X series from SN B090 [03038691-xx]
(for [03038058-xx] pneumatic unit)
Minor Maintenance
Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE X Series 33
Cleaning /Replacin g the Head Exhaus t Air Fil ter/X Mo tor Cooli ng
4.2.3.2 Cleaning/Replacing the Head Exhaust Air Filter/X Motor Cooling
Checking/Cleaning the Cooling Air Filter/Y Axes
4.2.3.3 Checking/Cleaning the Cooling Air Filter/Y Axes
Replacin g the Cool ing Air Filter/Y Ax es
4.2.3.4 Replacing the Cooling Air Filter/Y Axes
Remove the filter as described in "4.2.3.3 Checking/Cleaning the Cooling Air Filter/Y Axes" [ 33]
and replace it with a new filter [00376006-xx].
Remove the protective cover from the relevant
placement head.
Loosen the fastening screw (1) on the filter casing.
Check the "filter element 40 µm" [03003717-xx] (2)
for discoloration.
If you see discoloration, replace with a new one.
Fit the filter, the casing and the protective cover for
the placement head.
Repeat these steps for the filter elements of all
placement heads.
CAUTION! The main compressed air valve must
be closed for this work and the manometer set to zero!
Open the wing screw on the upper side of the filter (1)
and pull it up and out.
Check the filter for dirt and vacuum if required.
Push the pneumatic unit carefully back into the
machine and fix into place with the screw
provided (2).
CAUTION! Make sure that you do not pinch any
cables or hoses!
Open the main compressed air valve once more (1).
Close the door to the compressed air supply.
Minor Maintenance
Maintenance Tasks for Base Machine Performing Maintenance Tasks
34 Maintenance Manual SIPLACE X Series
Cleaning/Re placing the Fi lter on the Axis Unit and Com puter Unit
4.2.3.5 Cleaning/Replacing the Filter on the Axis Unit and Computer Unit
Cleaning/Re placing the Fi lter on the Pr otective Covers (X4I Only)
4.2.3.6 Cleaning/Replacing the Filter on the Protective Covers (X4I Only)
Replacing the filters in the protective covers
Remove the covers from the filters.
Use a suitable nozzle to vacuum the filters.
Check the filters for dirt.
If a filter is very dirty, replace with a new one.
Repeat these tasks for all eight fans.
Vacuum the filters in the protective covers of the
SIPLACE X4I from above.
Check the filters for dirt.
If the filters are very dirty, replace with new ones. (see
below)
Open the Safety Cover.
Loosen the screw (1) on the upper side of the fan.
Push the fan element up, and fold it down carefully.
CAUTION! Take care not to damage the fan
connection cable!
Replace the filter with a new metal filter [03076892-
xx].
Fit the fan and screw tight.