Minor Maintenance
Maintenance Tasks for Nozzles Performing Maintenance Tasks
50 Maintenance Manual SIPLACE X Series
Open the slide on the nozzle magazine.
Pull off the cleaning box, together with the nozzles.
CAUTION! Make sure that the nozzle tips do not
come into contact with the cleaning vessel or other metal
parts.
During cleaning, make sure that only the ceramic tips
come into direct contact with the cleaning fluid.
NOTICE! Use the cartridge rack 10xx
[03071700
-
xx] for C&P20 and CPP nozzles.
Fill the ultrasonic bath with distilled water. Make sure
you have the correct level. (1). Observe the following
instructions:
CAUTION
Filling level for ultrasonic bath
Only the ceramic tips may come into continuous contact with the cleaning fluid. These
should reach into the fluid by approx. 2 mm.
The water level should not exceed or undershoot the prescribed height by more than 2 mm
as this could impair the cleaning effect.
Minor Maintenance
Performing Maintenance Tasks Maintenance Tasks for Nozzles
Maintenance Manual SIPLACE X Series 51
Place the cleaning box with the nozzle tips facing
downwards into the ultrasonic bath.
CAUTION! The nozzle magazines may not be
placed into the water.
The recommended cleaning time for nozzles with normal
levels of dirt is 15 min.
The time needed depends on the degree of dirt.
At the end of the cleaning time, take the cleaning box
out of the ultrasonic bath.
Turn the cleaning box so that the nozzle tips face
upwards.
Place the guidance for the plastic brush into the
cleaning box.
Minor Maintenance
Maintenance Tasks for Nozzles Performing Maintenance Tasks
52 Maintenance Manual SIPLACE X Series
Replacin g Nozzle s
4.7.4.2 Replacing Nozzles
Apply slight pressure and move the brush back and
forth to remove the partially dissolved dirt and
residues.
Blow through the nozzles with compressed air.
(1) Remove the brush guidance.
Place the nozzles in the nozzle magazine and close
the slide (2).
Dry the nozzles with compressed air.
Place the nozzle magazine back in the nozzle
changer.
CAUTION! Reinsert the nozzle magazine into
the nozzle changer with the same orientation as before
(when it was removed before cleaning).
Remove a full nozzle magazine from the nozzle
changer. When handling a nozzle magazine which is
not full, make a note of the orientation in the nozzle
changer, to ensure correct reinsertion later on.
Check the nozzles and replace any dirty or damaged
ones.
Place the nozzle magazine back in the nozzle
changer. When handling a nozzle magazine which is
not full, pay attention to correct orientation in the
nozzle changer.
NOTICE! Prepare additional nozzle magazines
according to the current nozzle configuration and replace
the complete magazine.