AOI_RS_v85_en.pdf - 第116页
Chap ter3 SPC User Ma nual AOI Repair Station 1 12 b. D efect Rate: The formula is: Defect Rate=Defect Count/Subgroup Size c. Subgroup Size: Sample size d. U CL: Upper Control Limit of P chart. e. Standar d: Control Cent…

Chapter3 SPC User Manual
AOI Repair Station
111
−−
=
−
=
⇒
⇒
=
=
=
−=
+=
+++
=
+++
=
−=
+++
=
⇒
⇒
⇒
σσ
σ
σ
ˆ
3
,
ˆ
3
min
ˆ
6
ˆ
)(
)(
),,,min(),,,max(
)(
,,,
2
3
4
2
2
21
21
2121
21
21
XUSLLSLX
C
LSLUSL
C
LimitSpecLowerLSL
LimitSpecUpperUSL
d
R
RDLCL
RDUCL
ChartR
RAXLCL
RAXUCL
ChartX
k
RRR
R
k
XXX
X
XXXXXXR
n
XXX
X
countsubgroupk
sampleXXX
sizesamplen
pk
p
R
R
X
X
n
k
nn
n
n
L
L
LL
L
L
P Chart: If a user selects P Chart, the statistic data are as the
followings.
Every fields are explained below:
a. Defect Count: Total defect count.

Chapter3 SPC User Manual
AOI Repair Station
112
b. Defect Rate: The formula is:
Defect Rate=Defect Count/Subgroup Size
c. Subgroup Size: Sample size
d. UCL: Upper Control Limit of P chart.
e. Standard: Control Central Line of P chart.
f. LCL: Lower Control Limit of P chart.
g. Formula
P
Line
Central
Control
n
PP
PLCL
n
PP
PUCL
m
p
P
ratedefectsamplesp
samplingpersizesamplem
smplingofsetameansgroupasizegroupn
m
i
i
i
)1(
3
)1(
3
,
) (
1
−
−=
−
+=
=
⇒
⇒
⇒
∑
=

Chapter3 SPC User Manual
AOI Repair Station
113
7.3.5 Control display area: Below the statistical data are the control chart
display areas. These areas are located in the graphics display area on
the left and right side at the bottom of the screen. The different kinds of
control chart will display different graph for each monitored
component or solder.
X bar – R Chart: Each monitored component or solder will have
an X bar control chart and an R control chart as show below.
Description of the data
Data at right hand and left hand side: represents the
Upper Control Limit, Control Central Line and Lower
Control Limit.
Data lay below the control chart: displays the serial
X Bar control
R control chart
Description of the data on the right of the control chart:
Subgroup Size: sample size
Subgroup Recorded: number of samples selected.
Sigma: variable
Cp: Cp value
Cpk: Cpk value
X chart FAILS control rule(s): Alarm items violated by the X-bar control
chart up to the present
R chart FAILS control rule(s): Alarm items violated by the R control chart up
to the present