Nordson_EFD_GV_Series_Operating_Manual.pdf - 第33页
GV Series Automated Dispensing Systems 33 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. Secondary V iew Screen The Secondary View scre…

GV Series Automated Dispensing Systems
32 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Primary View Screen Right-Click Functions
When the Program tab is selected, all the commands for the open
dispense program are shown. Right-click on one or more selected
commands to open a right-click menu. The functions shown below can
be used on the selected commands.
Item Function
Copy Copies the selected command
Cut Copies and then deletes the selected command
Edit Opens the edit window for the selected command
Paste Pastes a cut or copied command into the selected command address
Change Command Type Changes the selected command to a different command type
Jump To Jumps to a specific Address command or Label command
Reflect Flips the selected commands along the X or Y axis, thus creating a mirror image.
An example is provided below.
Rotate Angle Rotates the selected commands by a specified number of degrees. An example is
provided below.
How to Reflect (Mirror) a Pattern
1. Select the lines to reflect, right-click to select REFLECT X or Y
2. The system mirrors the selected pattern
How to Rotate a Pattern
1. Select the lines to rotate, then right-click and select ROTATE ANGLE
2. Enter the desired degrees of rotation
3. The system rotates the selected pattern

GV Series Automated Dispensing Systems
33www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Secondary View Screen
The Secondary View screen changes depending on the selected tabs and icons.
Selected
Tab
Tab Color
When Selected
Secondary Screen Display Function
Program
When the Path icon is toggled ON: When the Path icon is toggled ON,
shows a visual representation of
the programmed pattern and the
Path mode icons:
• Refer to “Horizontal and Vertical
Toolbar Icons” on page35 for
an explanation of the icons.
• Refer to “Secondary View Screen
in Path View” on page34 for
additional path view functionality.
When the Path icon is toggled OFF:
When the Path icon is toggled OFF,
shows an actual view of the fixture
plate or workpiece surface as seen
by the camera.
Camera
Mark Library: Stores up to 240 mark files.
System
Setup
Path view and keypad: The keypad is used to enter
numeric values. Refer to “Keypad”
on page43.
Path iconMode icon (toggles
between Tip mode
and CCD mode)

GV Series Automated Dispensing Systems
34 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Secondary View Screen in Path View
Path View Point Colors
When the Secondary View screen is in the Path view (Path icon
toggled ON), it shows a visual representation of the programmed
pattern. The point colors represent the programmed point commands.
Point Command Color on Path View Screen
Line Start
Blue
Line Passing
Green
Line End
Olive
Arc Point
Orange
Path View Right Click Functions
On the Path view screen, right-click on any point (command) to open
a right-click menu. The functions shown below are available for the
selected point.
Path view line and point colors
Right-click on any point to open
the right-click menu
Item Function
Delete Point Deletes the selected point and connects the
previous command with the next command.
Optimize Path Opens a path for editing:
• Select Line Path Start and Line Path End to
edit the Line Start and Line End points of the
pattern.
• Select Arc Path Start and Arc Path End to
edit the beginning and end points of an Arc
point.
Select Line Selects entire pattern.
Reassignment
Start Point
Reassigns the Line Start point to the selected
point (the path must be closed).
Reverse Line Reverses the pattern.
Offset Closed
Line
Closes the pattern by adding a line from Line
Start to Line End and then reassigning Line
Start and Line End to be the same location.
• Offset Length (mm) enlarges the pattern
relative to the original pattern.
Fill Closed Area Fills an area of the pattern.
• Brush Width (mm): The distance between
each fill area spiral.
Add Line Passing
Right-click anywhere on the Path view grid (but not on a point) to
stitch a Line Passing point (command) to an existing point. Only
horizontal or vertical lines can be added.
Right-click to stitch a Line Passing
point onto an existing point